Volume of visual field assessed with kinetic perimetry and its application to static perimetry

John B. Christoforidis

Research output: Contribution to journalArticlepeer-review

11 Scopus citations

Abstract

Background: The purpose of this study was to quantify the volume of the kinetic visual field with a single unit that accounts for visual field area and differential luminance sensitivity. Methods: Kinetic visual field perimetry was performed with a Goldmann perimeter using I4e, I3e, I2e, and I1e targets. The visual fields of 25 normal volunteers (17 women, eight men) of mean age 33.9 ± 10.1 (range 17-64) years were obtained and digitized. Isopter areas were measured with a method devised to correct cartographic distortion due to polar projection inherent in perimetry and are expressed in steradians. The third dimension of each isopter represents sensitivity to target luminance and was calculated as log (target luminance-1). If luminance is expressed in cd/m2, the values for the third dimension are 0.5 for I4e, 1.0 for I3e, 1.5 for I2e, and 2.0 for I1e. The resulting unit is a steradian (log 103 (cd/m2)-1 which is referred to as a Goldmann. In addition, the visual fields of four patients with representative visual defect patterns were examined and compared with normal subjects. Results: Mean isopter areas for normal subjects were 3.092 ± 0.242 steradians for I4e, 2.349 ± 0.280 steradians for I3e, 1.242 ± 0.263 steradians for I2e, and 0.251 ± 0.114 steradians for the I1e target. Isopter volumes were 1.546 ± 0.121 Goldmanns for the I4e target, 1.174 ± 0.140 Goldmanns for I3e, 0.621 ± 0.131 Goldmanns for I2e, and 0.126 ± 0.057 Goldmanns for I1e. The total mean visual field volume in our study for the I target was 3.467 ± 0.371 Goldmanns. Conclusion: The volume of the island of vision may be used to quantify a visual field with a single value which contains information about both visual field extension and differential luminance sensitivity. This technique may be used to assess the progression or stability of visual field defects over time. A similar method may be applied to static perimetry.

Original languageEnglish (US)
Pages (from-to)535-541
Number of pages7
JournalClinical Ophthalmology
Volume5
Issue number1
DOIs
StatePublished - 2011

Keywords

  • Cartographic distortion
  • Kinetic perimetry
  • Static perimetry
  • Steradian
  • Visual field

ASJC Scopus subject areas

  • Ophthalmology

Fingerprint

Dive into the research topics of 'Volume of visual field assessed with kinetic perimetry and its application to static perimetry'. Together they form a unique fingerprint.

Cite this