TY - JOUR
T1 - Variable spatiotemporal resolution three-dimensional Dixon sequence for rapid dynamic contrast-enhanced breast MRI
AU - Saranathan, Manojkumar
AU - Rettmann, Dan W.
AU - Hargreaves, Brian A.
AU - Lipson, Jafi A.
AU - Daniel, Bruce L.
N1 - Publisher Copyright:
© 2013 Wiley Periodicals, Inc.
PY - 2014/12/1
Y1 - 2014/12/1
N2 - Materials and Methods: DISCO combines variable density, pseudorandom κ-space segmentation and two-point Dixon fat-water separation for high spatiotemporal resolution breast DCE MRI. During the contrast wash-in phase, view sharing is used to achieve high temporal resolution. Forty patients referred for breast MRI were imaged, 26 using the proposed DISCO sequence and 14 using a conventional low-spatial-resolution dynamic sequence (VIBRANT-FLEX) on a 3 Tesla scanner. DISCO dynamic images from 14 patients were compared with VIBRANT-FLEX images from 14 other patients. The image quality assessed by radiologist image ranking in a blinded manner, and the temporal characteristics of the two sequences were compared.Purpose: To investigate a new variable spatiotemporal resolution dynamic contrast-enhanced (DCE) MRI method termed DIfferential Subsampling with Cartesian Ordering (DISCO), for imaging of breast cancer.Results: A spatial resolution of 1.1 × 1.1 × 1.2 mm3 (160 slices, 28 cm field of view) was achieved with axial bilateral coverage in 120 s. Dynamic images with ∼9 s effective temporal resolution were generated during the 2-min contrast wash-in phase. The image quality of DISCO dynamic images ranked significantly higher than low spatial resolution VIBRANT-FLEX images (19.5 versus 9.5, Mann-Whitney U-test P = 0.00914), with no significant differences in the maximum slope of aortic enhancement.Conclusion: DISCO is a promising variablespatiotemporal-resolution imaging sequence for capturing the dynamics of rapidly enhancing tumors as well as structural features postcontrast. A near 1-mm isotropic spatial resolution was achieved with postcontrast static phase images in 120 s and dynamic phase images acquired in 9 s per phase.
AB - Materials and Methods: DISCO combines variable density, pseudorandom κ-space segmentation and two-point Dixon fat-water separation for high spatiotemporal resolution breast DCE MRI. During the contrast wash-in phase, view sharing is used to achieve high temporal resolution. Forty patients referred for breast MRI were imaged, 26 using the proposed DISCO sequence and 14 using a conventional low-spatial-resolution dynamic sequence (VIBRANT-FLEX) on a 3 Tesla scanner. DISCO dynamic images from 14 patients were compared with VIBRANT-FLEX images from 14 other patients. The image quality assessed by radiologist image ranking in a blinded manner, and the temporal characteristics of the two sequences were compared.Purpose: To investigate a new variable spatiotemporal resolution dynamic contrast-enhanced (DCE) MRI method termed DIfferential Subsampling with Cartesian Ordering (DISCO), for imaging of breast cancer.Results: A spatial resolution of 1.1 × 1.1 × 1.2 mm3 (160 slices, 28 cm field of view) was achieved with axial bilateral coverage in 120 s. Dynamic images with ∼9 s effective temporal resolution were generated during the 2-min contrast wash-in phase. The image quality of DISCO dynamic images ranked significantly higher than low spatial resolution VIBRANT-FLEX images (19.5 versus 9.5, Mann-Whitney U-test P = 0.00914), with no significant differences in the maximum slope of aortic enhancement.Conclusion: DISCO is a promising variablespatiotemporal-resolution imaging sequence for capturing the dynamics of rapidly enhancing tumors as well as structural features postcontrast. A near 1-mm isotropic spatial resolution was achieved with postcontrast static phase images in 120 s and dynamic phase images acquired in 9 s per phase.
KW - Dixon fat-water separation
KW - Dynamic contrast-enhanced breast MRI
KW - Time resolved imaging
KW - Variable spatiotemporal resolution
UR - http://www.scopus.com/inward/record.url?scp=84910016410&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84910016410&partnerID=8YFLogxK
U2 - 10.1002/jmri.24490
DO - 10.1002/jmri.24490
M3 - Article
C2 - 24227703
AN - SCOPUS:84910016410
SN - 1053-1807
VL - 40
SP - 1392
EP - 1399
JO - Journal of Magnetic Resonance Imaging
JF - Journal of Magnetic Resonance Imaging
IS - 6