TY - JOUR
T1 - Utility of pulse oximetry in the detection of arterial hypoxemia in liver transplant candidates
AU - Abrams, Gary A.
AU - Sanders, Michael K.
AU - Fallon, Michael B.
N1 - Funding Information:
The authors thank Julie Burks, RN, for data assembly and entry. Also, the authors acknowledge the support of the University of Alabama at Birmingham Liver Center Study Group: Miguel R. Arguedas, Joseph R. Bloomer, J. Steven Bynon, Devin E. Eckhoff, Brendan M. McGuire, Marty T. Sellers, Dirk J. van Leeuwen, and Anita Johnson.
PY - 2002
Y1 - 2002
N2 - Hepatopulmonary syndrome, arterial hypoxemia caused by intrapulmonary vasodilatation, occurs in approximately 10% of patients with cirrhosis. The severity of hypoxemia affects liver transplant candidacy and is associated with increased morbidity and mortality posttransplantation. Screening guidelines for detecting the presence of arterial hypoxemia do not exist. The aim of this study is to investigate the accuracy and utility of pulse oximetry in the detection of hypoxemia (PaO2 < 70 mm Hg) in patients with cirrhosis. Two hundred prospective liver transplant candidates were compared with 94 controls. Arterial oxyhemoglobin saturation was obtained by pulse oximetry (SPO2) and compared with simultaneous arterial blood gas (ABG) oxyhemoglobin values (SaO2; bias = the difference). PaO2, carboxyhemoglobin, methemoglobin, and routine clinical and biochemical parameters were investigated to account for the bias. SpO2 over-estimated SaO2 in 98% of patients with cirrhosis (mean bias, 3.37%; range, - 1% to 10%). Forty-four percent of patients with cirrhosis and controls had a bias of 4% or greater. No clinical or biochemical parameters of cirrhosis accounted for the overestimation of pulse oximetry. Twenty-five subjects with cirrhosis were hypoxemic, and an SpO2 of 97% or less showed a sensitivity of 96% and a positive likelihood ratio of 3.9 for detecting hypoxemia. An SpO2 of 94% or less detected all subjects with an arterial PaO2 less than 60 mm Hg. Pulse oximetry significantly overestimates arterial oxygenation, and the inaccuracy is not influenced by liver disease. Nevertheless, pulse oximetry can be a useful screening tool to detect arterial hypoxemia in patients with cirrhosis, but a higher threshold for obtaining an ABG must be used.
AB - Hepatopulmonary syndrome, arterial hypoxemia caused by intrapulmonary vasodilatation, occurs in approximately 10% of patients with cirrhosis. The severity of hypoxemia affects liver transplant candidacy and is associated with increased morbidity and mortality posttransplantation. Screening guidelines for detecting the presence of arterial hypoxemia do not exist. The aim of this study is to investigate the accuracy and utility of pulse oximetry in the detection of hypoxemia (PaO2 < 70 mm Hg) in patients with cirrhosis. Two hundred prospective liver transplant candidates were compared with 94 controls. Arterial oxyhemoglobin saturation was obtained by pulse oximetry (SPO2) and compared with simultaneous arterial blood gas (ABG) oxyhemoglobin values (SaO2; bias = the difference). PaO2, carboxyhemoglobin, methemoglobin, and routine clinical and biochemical parameters were investigated to account for the bias. SpO2 over-estimated SaO2 in 98% of patients with cirrhosis (mean bias, 3.37%; range, - 1% to 10%). Forty-four percent of patients with cirrhosis and controls had a bias of 4% or greater. No clinical or biochemical parameters of cirrhosis accounted for the overestimation of pulse oximetry. Twenty-five subjects with cirrhosis were hypoxemic, and an SpO2 of 97% or less showed a sensitivity of 96% and a positive likelihood ratio of 3.9 for detecting hypoxemia. An SpO2 of 94% or less detected all subjects with an arterial PaO2 less than 60 mm Hg. Pulse oximetry significantly overestimates arterial oxygenation, and the inaccuracy is not influenced by liver disease. Nevertheless, pulse oximetry can be a useful screening tool to detect arterial hypoxemia in patients with cirrhosis, but a higher threshold for obtaining an ABG must be used.
UR - http://www.scopus.com/inward/record.url?scp=0036250294&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0036250294&partnerID=8YFLogxK
U2 - 10.1053/jlts.2002.32252
DO - 10.1053/jlts.2002.32252
M3 - Article
C2 - 11965585
AN - SCOPUS:0036250294
SN - 1527-6465
VL - 8
SP - 391
EP - 396
JO - Liver Transplantation
JF - Liver Transplantation
IS - 4
ER -