Abstract
An improved analysis model is presented for predicting the local heat transfer coefficient of forced condensation in the annular flow region inside smooth horizontal tubes. Heat transfer experiments for R-12 and R-134a are conducted inside a condensing tube with an inner diameter of 11 mm and a length of 13 m. The mass flux ranged from 200 to 510 kg/m2s, and the vapor qualities varied from 1.0 to 0.0. Compared with the experimental data, the numerical results have a deviation of not more than 20% and 25% for 80% of the total 47 points of R-12 and 88% of the total 226 points of R-134a, respectively.
Original language | English (US) |
---|---|
Pages (from-to) | 34-43 |
Number of pages | 10 |
Journal | Heat Transfer Engineering |
Volume | 21 |
Issue number | 6 |
DOIs | |
State | Published - Nov 2000 |
Externally published | Yes |
ASJC Scopus subject areas
- Condensed Matter Physics
- Mechanical Engineering
- Fluid Flow and Transfer Processes