Abstract
The results of calibration tests on an air flowmeter instrument with a swivel plate were described. The investigations were carried out to ascertain the possibility of increasing the accuracy of constricting devices for gases. A flowmeter with changeable critical nozzles, calibrated on a test weight flowmeter instrument for gases, was used as the standard means of measurement.