TY - JOUR
T1 - The brighter-fatter effect in the JWST MIRI Si:As IBC detectors I. Observations, impact on science, and modeling
AU - Argyriou, Ioannis
AU - Lage, Craig
AU - Rieke, George H.
AU - Gasman, Danny
AU - Bouwman, Jeroen
AU - Morrison, Jane
AU - Libralato, Mattia
AU - Dicken, Daniel
AU - Brandl, Bernhard R.
AU - Álvarez-Márquez, Javier
AU - Labiano, Alvaro
AU - Regan, Michael
AU - Ressler, Michael E.
N1 - Publisher Copyright:
© The Authors 2023.
PY - 2023/12/1
Y1 - 2023/12/1
N2 - Context. The Mid-Infrared Instrument (MIRI) on board the James Webb Space Telescope (JWST) uses three Si:As impurity band conduction (IBC) detector arrays. The output voltage level of each MIRI detector pixel is digitally recorded by sampling up the ramp. For uniform or low-contrast illumination, the pixel ramps become nonlinear in a predictable way, but in areas of high contrast, the nonlinearity curve becomes much more complex. The origin of the effect is poorly understood and currently not calibrated out of the data. Aims. We provide observational evidence of the brighter-fatter effect (BFE) in MIRI conventional and high-contrast coronagraphic imaging, low-resolution spectroscopy, and medium-resolution spectroscopy data, and we investigate the physical mechanism that gives rise to the effect on the MIRI detector pixel raw voltage integration ramps. Methods. We used public data from the JWST/MIRI commissioning and Cycle 1 phase. We also developed a numerical electrostatic model of the MIRI detectors using a modified version of the public Poisson_CCD code. Results. We find that the physical mechanism behind the BFE manifesting in MIRI data is fundamentally different to that of chargecoupled devices and photodiode arrays such as the Hawaii-XRG near-infrared detectors used by the NIRISS, NIRCam, and NIRSpec instruments on board JWST. Observationally, the BFE makes the JWST MIRI data yield 10-25% larger point sources and spectral line profiles as a function of the relative level of de-biasing of neighboring detector pixels. This broadening impacts the MIRI absolute flux calibration, time-series observations of faint companions, and point spread function modeling and subtraction. We also find that the intra-pixel 2D profile of the shrinking Si:As IBC detector depletion region directly impacts the accuracy of the pixel ramp nonlinearity calibration model.
AB - Context. The Mid-Infrared Instrument (MIRI) on board the James Webb Space Telescope (JWST) uses three Si:As impurity band conduction (IBC) detector arrays. The output voltage level of each MIRI detector pixel is digitally recorded by sampling up the ramp. For uniform or low-contrast illumination, the pixel ramps become nonlinear in a predictable way, but in areas of high contrast, the nonlinearity curve becomes much more complex. The origin of the effect is poorly understood and currently not calibrated out of the data. Aims. We provide observational evidence of the brighter-fatter effect (BFE) in MIRI conventional and high-contrast coronagraphic imaging, low-resolution spectroscopy, and medium-resolution spectroscopy data, and we investigate the physical mechanism that gives rise to the effect on the MIRI detector pixel raw voltage integration ramps. Methods. We used public data from the JWST/MIRI commissioning and Cycle 1 phase. We also developed a numerical electrostatic model of the MIRI detectors using a modified version of the public Poisson_CCD code. Results. We find that the physical mechanism behind the BFE manifesting in MIRI data is fundamentally different to that of chargecoupled devices and photodiode arrays such as the Hawaii-XRG near-infrared detectors used by the NIRISS, NIRCam, and NIRSpec instruments on board JWST. Observationally, the BFE makes the JWST MIRI data yield 10-25% larger point sources and spectral line profiles as a function of the relative level of de-biasing of neighboring detector pixels. This broadening impacts the MIRI absolute flux calibration, time-series observations of faint companions, and point spread function modeling and subtraction. We also find that the intra-pixel 2D profile of the shrinking Si:As IBC detector depletion region directly impacts the accuracy of the pixel ramp nonlinearity calibration model.
KW - infrared: general
KW - instrumentation: detectors
KW - methods: data analysis
KW - methods: numerical
UR - http://www.scopus.com/inward/record.url?scp=85180779228&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85180779228&partnerID=8YFLogxK
U2 - 10.1051/0004-6361/202346490
DO - 10.1051/0004-6361/202346490
M3 - Article
AN - SCOPUS:85180779228
SN - 0004-6361
VL - 680
JO - Astronomy and astrophysics
JF - Astronomy and astrophysics
M1 - A96
ER -