Abstract
A foam model of a protrusio acetabulum with cylindrical voids of varying diameters was used to test acetabular components for their ability to resist migration within the defect. A bipolar component, a hemispherical cup, and a hemispherical cup with peripheral rim augmentation were tested in defects with diameters ranging from 1 to 3 mm less than the major diameter of the component. The cup with peripheral rim augmentation demonstrated 20% to 40% greater resistance to migration than the hemispherical cup, depending on the extent of under-reaming, with the bipolar component consistently demonstrating the lowest load to failure. The results of this study confirm the less-than-satisfactory clinical results seen with bipolar reconstruction of protrusio acetabuli, and support the use of 'fixed' cups in these settings.
Original language | English (US) |
---|---|
Pages (from-to) | 307-310 |
Number of pages | 4 |
Journal | Orthopedics |
Volume | 20 |
Issue number | 4 |
State | Published - Apr 1997 |
ASJC Scopus subject areas
- Surgery
- Orthopedics and Sports Medicine