Abstract
The design of an electrochemical sensor to measure wafer contaminant concentrations during ultrapure water rinses is discussed in the article. The techniques discussed in this paper also demonstrate the need to have additional monitor devices on-chip that enable the characterization of unwanted parasitic devices. The results obtained from the experiments conducted will provide, for the first time, data on the removal rates of contaminants from deep trenches, thereby enabling the identification of mechanisms and the development of models for wafer contaminant removal in advance semiconductor processes.
Original language | English (US) |
---|---|
Pages | 209-213 |
Number of pages | 5 |
State | Published - 2003 |
Event | IEEE International Conference on Microelectronic Test Structures - Monterey, CA, United States Duration: Mar 17 2003 → Mar 20 2003 |
Other
Other | IEEE International Conference on Microelectronic Test Structures |
---|---|
Country/Territory | United States |
City | Monterey, CA |
Period | 3/17/03 → 3/20/03 |
ASJC Scopus subject areas
- Electrical and Electronic Engineering