Abstract
Purpose: To investigate post acquisition scatter correction for digital tomosynthesis breast imaging. Method and Materials: Images of a composite phantom that was fabricated for evaluating digital breast tomosynthesis and used in a previous contrast‐detail (CD) study [Suryanarayanan et al., Acad Radiol 7: 1085–1097, 2000] were used to test the scatter correction method. These images were acquired using a prototype full‐field digital mammography (FFDM) system (GE Medical Systems, Milwaukee, WI) without an anti‐scatter grid. The phantom comprised of a centrally placed CD insert (MedOptics, Tucson, AZ), blocks of cluttered paraffin and polymethyl methacrylate (PMMA), and beeswax surrounding it to provide a total phantom thickness of 54 mm. A set of 7 projection images of the phantom were acquired over an angular range of ± 18° at 60 intervals at 26 kVp, MoMo, and 32 mAs/view. The projection data sets were corrected for scatter using the scatter correction technique described by Trotter et al. [Proc. SPIE, vol. 4682: 469–478, 2002] and processed with an adaptive noise filter. The projection images were then reconstructed using back‐projection and iterative restoration methods using Tuned Aperture Computed Tomography (TACT) [Webber et al., J. Digit. Imaging, 13: 90–97, 2000] software (developed by R.L. Webber, Wake Forest University, NC). The contrast‐to‐noise (CNR) ratio, signal‐to‐noise ratio (SNR), and % contrast were computed for one of the targets (2.32 mm diameter and 0.24 mm depth). Results: The uncorrected projection data set reconstructed with back‐projection resulted in CNR = 3.0, SNR = 30.4, and % contrast = 11.1, while the scatter corrected and processed projection images yielded CNR = 10.2, SNR =60.7, and %contrast = 20.2. Conclusion: The results of this study indicate improved SNR, CNR, and % contrast after scatter correction in tomosynthesis. We are currently implementing and evaluating other scatter correction and reconstruction methods for digital tomosynthesis.
Original language | English (US) |
---|---|
Pages (from-to) | 1911-1912 |
Number of pages | 2 |
Journal | Medical physics |
Volume | 32 |
Issue number | 6 |
DOIs | |
State | Published - Jun 2005 |
Externally published | Yes |
ASJC Scopus subject areas
- Biophysics
- Radiology Nuclear Medicine and imaging