TY - JOUR
T1 - Sparing of the penile bulb and proximal penile structures with intensity-modulated radiation therapy for prostate cancer
AU - Kao, J.
AU - Turian, J.
AU - Meyers, A.
AU - Hamilton, R. J.
AU - Smith, B.
AU - Vijayakumar, S.
AU - Jani, Ashesh B.
PY - 2004/2
Y1 - 2004/2
N2 - Quality of life is an important consideration in the treatment of early prostate cancer. Laboratory and clinical data suggest that higher radiation doses delivered to the bulb of penis and proximal penile structures correlates with higher rates of post-radiation impotence. The goal of this investigation was to determine if intensity-modulated radiation therapy (IMRT) spares dose to the penile bulb while maintaining coverage of the prostate. 10 consecutive patients with clinically organ confined prostate cancer were planned with 3D conformal radiation therapy (3D-CRT) or IMRT to give a dose of 74 Gy without specifically constraining the plans to spare the penile bulb. All 10 patients were ultimately treated with IMRT. Dose-volume histograms were evaluated and the doses to prostate, rectum, bladder and penile bulb were compared. IMRT reduced the mean penile bulb doses compared with 3D-CRT (33.2 Gy vs 48.9 Gy, p<0.001), the percentage of penile bulb receiving over 40 Gy (37.7% vs 67.2%, p<0.001) and the dose received by >95% of penile bulb (5.3 Gy vs 11.7 Gy, p=0.003). Maximum penile bulb doses were higher with IMRT (81.2 Gy vs 73.1 Gy, p<0.001) although the volume of this high dose region was small. Both methods resulted in similar coverage of the prostate. The volume of rectum receiving 70 Gy was significantly reduced with IMRT (18.4% vs 21.9%, p=0.003) but the volumes of bladder receiving 70 Gy were similar (p=0.3). IMRT may potentially reduce long term sexual morbidity by reducing the dose to the majority of the penile bulb.
AB - Quality of life is an important consideration in the treatment of early prostate cancer. Laboratory and clinical data suggest that higher radiation doses delivered to the bulb of penis and proximal penile structures correlates with higher rates of post-radiation impotence. The goal of this investigation was to determine if intensity-modulated radiation therapy (IMRT) spares dose to the penile bulb while maintaining coverage of the prostate. 10 consecutive patients with clinically organ confined prostate cancer were planned with 3D conformal radiation therapy (3D-CRT) or IMRT to give a dose of 74 Gy without specifically constraining the plans to spare the penile bulb. All 10 patients were ultimately treated with IMRT. Dose-volume histograms were evaluated and the doses to prostate, rectum, bladder and penile bulb were compared. IMRT reduced the mean penile bulb doses compared with 3D-CRT (33.2 Gy vs 48.9 Gy, p<0.001), the percentage of penile bulb receiving over 40 Gy (37.7% vs 67.2%, p<0.001) and the dose received by >95% of penile bulb (5.3 Gy vs 11.7 Gy, p=0.003). Maximum penile bulb doses were higher with IMRT (81.2 Gy vs 73.1 Gy, p<0.001) although the volume of this high dose region was small. Both methods resulted in similar coverage of the prostate. The volume of rectum receiving 70 Gy was significantly reduced with IMRT (18.4% vs 21.9%, p=0.003) but the volumes of bladder receiving 70 Gy were similar (p=0.3). IMRT may potentially reduce long term sexual morbidity by reducing the dose to the majority of the penile bulb.
UR - http://www.scopus.com/inward/record.url?scp=1542299570&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=1542299570&partnerID=8YFLogxK
U2 - 10.1259/bjr/37893924
DO - 10.1259/bjr/37893924
M3 - Article
C2 - 15010385
AN - SCOPUS:1542299570
SN - 0007-1285
VL - 77
SP - 129
EP - 136
JO - British Journal of Radiology
JF - British Journal of Radiology
IS - 914
ER -