TY - JOUR
T1 - Scientifically Operated CCD-Based Spectroscopic System for High-Precision Spectrometric Determinations of Seawater
AU - Pomeroy, Robert S.
AU - Baker, Mark E.
AU - Denton, M. Bonner
AU - Dickson, Andrew G.
N1 - Publisher Copyright:
© 1995 Society for Applied Spectroscopy.
PY - 1995/12
Y1 - 1995/12
N2 - The application of an aberration-corrected imaging spectrograph with the use of fiber-optic inputs and a charge-coupled device detector to produce a sensitive, flexible, and rugged spectroscopic system capable of employment in remote sensing and field applications is presented. This investigation focuses on the optical system design, detector characteristics, and modes of operation that will result in a field instrument capable of both sensitive fluorescence and high-precision absorbance measurements. Evaluation of the optical system used the spectroscopic determination of seawater pH as the test case. Spectral measurements were made with the use of thymol blue as a pH indicator for absorbance and 7-hydroxy-coumarin as the fluorescence pH indicator. This system displayed excellent precision for both absorbance and fluorescence analyses; RSDs for absorbance and fluorescence of ±0.00065 and ±0.0015 in pH, respectively, were experimentally obtained. These findings, along with the advantages of the area array detector to provide simultaneous multiwavelength, multianalyte spectral analysis in a single, rugged optical system, make a strong case for the application of scientifically operated solid-state detector systems to remote sensing and field instrumentation.
AB - The application of an aberration-corrected imaging spectrograph with the use of fiber-optic inputs and a charge-coupled device detector to produce a sensitive, flexible, and rugged spectroscopic system capable of employment in remote sensing and field applications is presented. This investigation focuses on the optical system design, detector characteristics, and modes of operation that will result in a field instrument capable of both sensitive fluorescence and high-precision absorbance measurements. Evaluation of the optical system used the spectroscopic determination of seawater pH as the test case. Spectral measurements were made with the use of thymol blue as a pH indicator for absorbance and 7-hydroxy-coumarin as the fluorescence pH indicator. This system displayed excellent precision for both absorbance and fluorescence analyses; RSDs for absorbance and fluorescence of ±0.00065 and ±0.0015 in pH, respectively, were experimentally obtained. These findings, along with the advantages of the area array detector to provide simultaneous multiwavelength, multianalyte spectral analysis in a single, rugged optical system, make a strong case for the application of scientifically operated solid-state detector systems to remote sensing and field instrumentation.
KW - Absorbance spectroscopy
KW - Charge-coupled device
KW - Fluorescence spectroscopy
KW - Seawater analysis
UR - http://www.scopus.com/inward/record.url?scp=0001617085&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0001617085&partnerID=8YFLogxK
U2 - 10.1366/0003702953965939
DO - 10.1366/0003702953965939
M3 - Article
AN - SCOPUS:0001617085
SN - 0003-7028
VL - 49
SP - 1729
EP - 1736
JO - Applied Spectroscopy
JF - Applied Spectroscopy
IS - 12
ER -