T1 - Robotic system for MRI-guided shoulder arthrography
T2 - 2018 International Symposium on Medical Robotics, ISMR 2018
AU - Patel, Niravkumar A.
AU - Azimi, Ehsan
AU - Monfaredi, Reza
AU - Sharma, Karun
AU - Cleary, Kevin
AU - Iordachita, Iulian
N1 - Publisher Copyright:
© 2018 IEEE.
PY - 2018/4/6
Y1 - 2018/4/6
N2 - This paper introduces a body mounted robotic system for MRI-guided shoulder arthrography in pediatric patients. This robotic manipulator is optimized for being accurate yet light enough to perform the contrast agent injection and joint examination imaging inside the MRI bore. The robotic manipulator has 4 degrees of freedom (DOF) providing accurate insertion trajectory of the injection needle. In shoulder arthrography procedures, contrast agent is injected under fluoroscope guidance resulting in radiation exposure which should be avoided for pediatric patients. Also after contrast agent injection typically MRI images are acquired for examination resulting in two stage procedure. The presented system allows clinicians to perform both contrast agent injection and joint examination under MRI guidance, hence completely eliminating radiation exposure from fluoroscope guidance and patient movement from X-Ray/CT room to MRI suite. The presented system contains no ferrous components and is considered MR-Conditional. The bench-top accuracy evaluation of the robotic manipulator shows average pose error of 1.22 mm in position and 1 degree in orientation at the needle tip.
AB - This paper introduces a body mounted robotic system for MRI-guided shoulder arthrography in pediatric patients. This robotic manipulator is optimized for being accurate yet light enough to perform the contrast agent injection and joint examination imaging inside the MRI bore. The robotic manipulator has 4 degrees of freedom (DOF) providing accurate insertion trajectory of the injection needle. In shoulder arthrography procedures, contrast agent is injected under fluoroscope guidance resulting in radiation exposure which should be avoided for pediatric patients. Also after contrast agent injection typically MRI images are acquired for examination resulting in two stage procedure. The presented system allows clinicians to perform both contrast agent injection and joint examination under MRI guidance, hence completely eliminating radiation exposure from fluoroscope guidance and patient movement from X-Ray/CT room to MRI suite. The presented system contains no ferrous components and is considered MR-Conditional. The bench-top accuracy evaluation of the robotic manipulator shows average pose error of 1.22 mm in position and 1 degree in orientation at the needle tip.
UR - https://www.scopus.com/pages/publications/85050635419
UR - https://www.scopus.com/pages/publications/85050635419#tab=citedBy
U2 - 10.1109/ISMR.2018.8333299
DO - 10.1109/ISMR.2018.8333299
M3 - Conference contribution
AN - SCOPUS:85050635419
T3 - 2018 International Symposium on Medical Robotics, ISMR 2018
SP - 1
EP - 6
BT - 2018 International Symposium on Medical Robotics, ISMR 2018
PB - Institute of Electrical and Electronics Engineers Inc.
Y2 - 1 March 2018 through 3 March 2018
ER -