TY - JOUR
T1 - Respirator physiological effects under simulated work conditions
AU - Bansal, Siddharth
AU - Harber, Philip
AU - Yun, David
AU - Liu, David
AU - Liu, Yihang
AU - Wu, Samantha
AU - Ng, David
AU - Santiago, Silverio
N1 - Funding Information:
T his study was supported by grant # R01 OH-8119 from CDC/NIOSH.
PY - 2009/4
Y1 - 2009/4
N2 - This study compared the physiological impacts of two respirator types in simulated work conditions. Fifty-six subjects included normal volunteers and persons with mild respiratory impairments (chronic rhinitis, mild COPD, and mild asthma). Respiratory parameters and electrocardiogram were measured using respiratory inductive plethysmography while performing eight work tasks involving low to moderate exertion using two respirators: (1) a dual cartridge half face mask (HFM) respirator, and (2) the N95. Mixed model regression analyses evaluating the effect of task and respirator type showed that task affected tidal volume, minute ventilation, breathing frequency and heart rate; all were greater in heavier tasks. Although respirator type did not affect respiratory volume parameters and flow rates, the HFM led to increase in the inspiratory time, reduction of the expiratory time, and increase in the duty cycle in comparison with the N95. The magnitude of differences was relatively small. The results suggest that most individuals, including persons with mild respiratory impairments, will physiologically tolerate either type of respirator at low to moderate exertion tasks. However, because effective protection depends on proper use, differences in subjective effect may have greater impact than physiological differences. Using respirators may be feasible on a widespread basis if necessary for maintaining essential services in the face of widespread concern about an infectious or terrorist threat.
AB - This study compared the physiological impacts of two respirator types in simulated work conditions. Fifty-six subjects included normal volunteers and persons with mild respiratory impairments (chronic rhinitis, mild COPD, and mild asthma). Respiratory parameters and electrocardiogram were measured using respiratory inductive plethysmography while performing eight work tasks involving low to moderate exertion using two respirators: (1) a dual cartridge half face mask (HFM) respirator, and (2) the N95. Mixed model regression analyses evaluating the effect of task and respirator type showed that task affected tidal volume, minute ventilation, breathing frequency and heart rate; all were greater in heavier tasks. Although respirator type did not affect respiratory volume parameters and flow rates, the HFM led to increase in the inspiratory time, reduction of the expiratory time, and increase in the duty cycle in comparison with the N95. The magnitude of differences was relatively small. The results suggest that most individuals, including persons with mild respiratory impairments, will physiologically tolerate either type of respirator at low to moderate exertion tasks. However, because effective protection depends on proper use, differences in subjective effect may have greater impact than physiological differences. Using respirators may be feasible on a widespread basis if necessary for maintaining essential services in the face of widespread concern about an infectious or terrorist threat.
KW - Physiology
KW - Plethysmography
KW - Pulmonary ventilation
KW - Respirator
KW - Terrorism
UR - http://www.scopus.com/inward/record.url?scp=61649117750&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=61649117750&partnerID=8YFLogxK
U2 - 10.1080/15459620902729218
DO - 10.1080/15459620902729218
M3 - Article
C2 - 19180375
AN - SCOPUS:61649117750
SN - 1545-9624
VL - 6
SP - 221
EP - 227
JO - Journal of occupational and environmental hygiene
JF - Journal of occupational and environmental hygiene
IS - 4
ER -