Psychometric comparison of the PROMIS physical function CAT with the FAAM and FFI for measuring patient-reported outcomes

  • Man Hung
  • , Judith F. Baumhauer
  • , James W. Brodsky
  • , Christine Cheng
  • , Scott J. Ellis
  • , Jeremy D. Franklin
  • , Shirley D. Hon
  • , Susan N. Ishikawa
  • , L. Daniel Latt
  • , Phinit Phisitkul
  • , Charles L. Saltzman
  • , Nelson F. SooHoo
  • , Kenneth J. Hunt

Research output: Contribution to journalArticlepeer-review

118 Scopus citations

Abstract

Background: Selecting optimal patient-reported outcome (PRO) instruments is critical to improving the quality of health care. The purpose of this study was to compare the reliability, responsiveness, and efficiency of three PRO measures: the Foot and Ankle Ability Measure-Activity of Daily Living subscale (FAAM-ADL), the Foot Function Index 5-point verbal rating scale (FFI-5pt), and the PROMIS Physical Function computerized adaptive test (PF CAT). Methods: Data were aggregated from 10 clinical sites in the AOFAS's National Orthopaedic Foot and Ankle Research (OFAR) Network from 311 patients who underwent elective surgery for a disorder of the foot or ankle. Patients were administered the FAAM-ADL, FFI-5pt, and PF CAT at their preoperative visit and at 6 months after surgery. Reliabilities were evaluated using a Rasch model. Responsiveness was calculated using paired samples t test and efficiency was recorded as number of seconds to complete the instrument. Results: Similar reliabilities were found for the three instruments. Item reliabilities for FAAM-ADL, FFI-5pt, and PF CAT were all .99. Pearson reliabilities for FAAM-ADL, FFI-5pt, and PF CAT were .95, .93, and .96, respectively. On average, patients completed the FAAM-ADL in 179 seconds, the FFI-5pt in 194 seconds, and the PF CAT in 44 seconds, (P < .001). The PF CAT and FAAM-ADL showed significant improvement (P = .01 and P = .001, respectively) in patients' physical function after treatment; the FFI-5pt did not show improvement. Conclusions: Overall, the PF CAT performed best in terms of reliability, responsiveness, and efficiency in this broad sample of foot and ankle patients. It can be a potential replacement for the conventional PRO measures, but further validation is needed in conjunction with the PROMIS Pain instruments.

Original languageEnglish (US)
Pages (from-to)592-599
Number of pages8
JournalFoot and Ankle International
Volume35
Issue number6
DOIs
StatePublished - Jun 2014

Keywords

  • Computerized adaptive testing
  • FAAM
  • FFI
  • OFAR
  • PROMIS
  • Patient-reported outcomes
  • Physical function
  • Psychometrics

ASJC Scopus subject areas

  • Surgery
  • Orthopedics and Sports Medicine

Fingerprint

Dive into the research topics of 'Psychometric comparison of the PROMIS physical function CAT with the FAAM and FFI for measuring patient-reported outcomes'. Together they form a unique fingerprint.

Cite this