Abstract
The purpose of this bench-top study was to demonstrate the feasibility and effect of applying ozone and ozone/peroxide upstream of reverse osmosis (RO) membranes as a means of controlling organic fouling during reuse applications. A series of ozone or ozone/peroxide doses was applied to surface water and a membrane bioreactor (MBR) filtrate using a HiPOx® reactor skid, with ozone-to-dissolved organic carbon ratios of approximately 0.25 to 1.75. Results from the flat-sheet testing indicate that both ozoneand ozone/peroxide-treated waters, even at the lowest ozone dose of 1.5 mg/L, fouled the membranes less than the MBR filtrate and surface control waters while both treated and control waters maintained consistent levels of salt rejection throughout the tests.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 379-388 |
| Number of pages | 10 |
| Journal | Ozone: Science and Engineering |
| Volume | 33 |
| Issue number | 5 |
| DOIs | |
| State | Published - Sep 2011 |
| Externally published | Yes |
Keywords
- Fouling
- Membranes
- Organic Matter
- Ozone
- Reuse
- Reverse Osmosis
ASJC Scopus subject areas
- Environmental Engineering
- Environmental Chemistry