TY - JOUR
T1 - Postcesarean epidural morphine
T2 - A dose-response study
AU - Palmer, Craig M.
AU - Nogami, Wallace M.
AU - Van Maren, Gretchen
AU - Alves, Diane M.
PY - 2000
Y1 - 2000
N2 - The purpose of this study was to describe the dose-response relationship of epidural morphine for postcesarean analgesia for quality of analgesia and relation to the side effects of pruritus, nausea, and vomiting. Sixty term parturients undergoing nonurgent cesarean delivery were enrolled and randomized to receive a single dose of epidural morphine after delivery (0,1.25, 2.5, 3.75, or 5 mg). A patient-controlled analgesia (PCA) device provided free access to additional analgesics. PCA morphine use and the incidence and severity of side effects were recorded for 24 h. Data were analyzed with analysis of variance, Student's t-tests, and χ2 analysis. Nonlinear regression was used to describe a dose-response curve. PCA use differed significantly among groups (P < 0.001); PCA use was significantly greater in Group 0 mg than Groups 2.5, 3.75, and 5 mg (P < 0.05). PCA use was also significantly greater in Group 1.25 mg than Groups 3.75 and 5 mg (P < 0.05). Pruritus scores were significantly higher in all groups given epidural morphine than the control group (0 mg) (P < 0.05), but did not differ among the treatment groups (1.25-5 mg), although pruritus scores were significantly higher in treatment groups than in the control (P < 0.05). No relation was found between epidural morphine dose and incidence or severity of nausea and vomiting. We concluded that, for optimal analgesia, augmentation of epidural morphine with systemic analgesics or other epidural medications may be necessary. Implications: Quality of analgesia increases as the dose of epidural morphine increases to at least 3.75 mg; increasing the dose further to 5 mg did not improve analgesia. Side effects were not dose related. For optimal analgesia, augmentation of epidural morphine with systemic analgesics or other epidural medications may be necessary.
AB - The purpose of this study was to describe the dose-response relationship of epidural morphine for postcesarean analgesia for quality of analgesia and relation to the side effects of pruritus, nausea, and vomiting. Sixty term parturients undergoing nonurgent cesarean delivery were enrolled and randomized to receive a single dose of epidural morphine after delivery (0,1.25, 2.5, 3.75, or 5 mg). A patient-controlled analgesia (PCA) device provided free access to additional analgesics. PCA morphine use and the incidence and severity of side effects were recorded for 24 h. Data were analyzed with analysis of variance, Student's t-tests, and χ2 analysis. Nonlinear regression was used to describe a dose-response curve. PCA use differed significantly among groups (P < 0.001); PCA use was significantly greater in Group 0 mg than Groups 2.5, 3.75, and 5 mg (P < 0.05). PCA use was also significantly greater in Group 1.25 mg than Groups 3.75 and 5 mg (P < 0.05). Pruritus scores were significantly higher in all groups given epidural morphine than the control group (0 mg) (P < 0.05), but did not differ among the treatment groups (1.25-5 mg), although pruritus scores were significantly higher in treatment groups than in the control (P < 0.05). No relation was found between epidural morphine dose and incidence or severity of nausea and vomiting. We concluded that, for optimal analgesia, augmentation of epidural morphine with systemic analgesics or other epidural medications may be necessary. Implications: Quality of analgesia increases as the dose of epidural morphine increases to at least 3.75 mg; increasing the dose further to 5 mg did not improve analgesia. Side effects were not dose related. For optimal analgesia, augmentation of epidural morphine with systemic analgesics or other epidural medications may be necessary.
UR - http://www.scopus.com/inward/record.url?scp=0034066210&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0034066210&partnerID=8YFLogxK
U2 - 10.1213/00000539-200004000-00021
DO - 10.1213/00000539-200004000-00021
M3 - Article
C2 - 10735794
AN - SCOPUS:0034066210
SN - 0003-2999
VL - 90
SP - 887
EP - 891
JO - Anesthesia and analgesia
JF - Anesthesia and analgesia
IS - 4
ER -