TY - JOUR
T1 - Polysomnography performed in the unattended home versus the attended laboratory setting - Sleep Heart Health Study methodology
AU - Iber, Conrad
AU - Redline, Susan
AU - Gilpin, Adele M.Kaplan
AU - Quan, Stuart F.
AU - Zhang, Lin
AU - Gottlieb, Daniel J.
AU - Rapoport, David
AU - Resnick, Helaine E.
AU - Sanders, Mark
AU - Smith, Philip
PY - 2004
Y1 - 2004
N2 - Study Objective: To compare polysomnographic recordings obtained in the home and laboratory setting. Design and Setting: Multicenter study comparing unsupervised polysomnography performed in the participant's home with polysomnography supervised at an academic sleep disorders center, using a randomized sequence of study setting. Sleep Heart Health Study (SHHS) standardized polysomnographic recording and scoring techniques were used for both settings. Participants: 64 of 76 non-SHHS participants recruited from 7 SHHS field sites who had both a laboratory and home polysomnogram meeting acceptable quality criteria. Measurements and Results: Median sleep duration was greater in the home than in the laboratory (375 vs 318 minutes, respectively, P < .0001) as was sleep efficiency (86% vs 82%, respectively, P < .0024). Very small, but significant increases in percentage of rapid eye movement sleep and decreases in stage 1 sleep were noted in the laboratory. Employing multiple definitions of respiratory disturbance index (RDI), median RDI was similar in both settings (for example, RDI with 3% desaturation: home 12.4, range 0.6-67; laboratory 9.5, range 0.1-93.4, P = .41). Quartile analysis of laboratory RDI showed moderate agreement with home RDI measurements. Based on the mean of laboratory and home RDI and using a outpoint of 20, there was a biphasic distribution, with the RDI 3% above 20 being more common in the recordings performed in the laboratory than in the home and below 20 being more common in the recordings performed in the home than in the laboratory. These differences could not be attributed to quality of recording, age, sex, or body mass index. Conclusions: Using SHHS methodology, median RDI was similar in the unattended home and attended laboratory setting with differences of small magnitude in some sleep parameters. Differences in RDI between settings resulted in a rate of disease misclassification that is similar to repeated studies in the same setting.
AB - Study Objective: To compare polysomnographic recordings obtained in the home and laboratory setting. Design and Setting: Multicenter study comparing unsupervised polysomnography performed in the participant's home with polysomnography supervised at an academic sleep disorders center, using a randomized sequence of study setting. Sleep Heart Health Study (SHHS) standardized polysomnographic recording and scoring techniques were used for both settings. Participants: 64 of 76 non-SHHS participants recruited from 7 SHHS field sites who had both a laboratory and home polysomnogram meeting acceptable quality criteria. Measurements and Results: Median sleep duration was greater in the home than in the laboratory (375 vs 318 minutes, respectively, P < .0001) as was sleep efficiency (86% vs 82%, respectively, P < .0024). Very small, but significant increases in percentage of rapid eye movement sleep and decreases in stage 1 sleep were noted in the laboratory. Employing multiple definitions of respiratory disturbance index (RDI), median RDI was similar in both settings (for example, RDI with 3% desaturation: home 12.4, range 0.6-67; laboratory 9.5, range 0.1-93.4, P = .41). Quartile analysis of laboratory RDI showed moderate agreement with home RDI measurements. Based on the mean of laboratory and home RDI and using a outpoint of 20, there was a biphasic distribution, with the RDI 3% above 20 being more common in the recordings performed in the laboratory than in the home and below 20 being more common in the recordings performed in the home than in the laboratory. These differences could not be attributed to quality of recording, age, sex, or body mass index. Conclusions: Using SHHS methodology, median RDI was similar in the unattended home and attended laboratory setting with differences of small magnitude in some sleep parameters. Differences in RDI between settings resulted in a rate of disease misclassification that is similar to repeated studies in the same setting.
UR - http://www.scopus.com/inward/record.url?scp=3543017342&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=3543017342&partnerID=8YFLogxK
U2 - 10.1093/sleep/27.3.536
DO - 10.1093/sleep/27.3.536
M3 - Article
C2 - 15164911
AN - SCOPUS:3543017342
SN - 0161-8105
VL - 27
SP - 536
EP - 540
JO - Sleep
JF - Sleep
IS - 3
ER -