TY - JOUR
T1 - Peripheral light-focusing
T2 - Measurement reliability and correlations with ocular dimensions
AU - Twelker, J. Daniel
AU - Harbison, Shauna C.
AU - Bailey, Ian L.
PY - 2005/2
Y1 - 2005/2
N2 - Purpose. When a beam of light is directed toward the temporal limbus from an angle of about 120° temporal to the primary line of sight, an illuminated patch appears on the sclera at the nasal limbus. An optical apparatus was developed for measuring the angular range of this optical phenomenon, often called the temporal catchment angle. It is possible that the temporal catchment angle or its correlates could serve as a key risk factor for the development of pterygia or cortical cataract. Methods. We built an apparatus that allows variation in the angle of a beam directed toward the temporal limbus. Two examiners measured the angular catchment range over which peripheral light focusing occurred for the right eyes of 30 subjects. Other anterior segment dimensions, including palpebral aperture height, refractive error, central and peripheral corneal power, anterior chamber depth, and corneal diameter, were measured. Results. There was no statistically or clinically significant difference between the repeated measures of the examiners. The mean temporal catchment angle was 17.1° (SD, 6.5). The intraobserver and interobserver 95% limits of agreement were 6.2 and 9.7°, respectively. The mean posterior limit was 121.0° (SD, 5.5), and the mean anterior limit was 104.1° (SD, 6.5) from the primary line of sight. The temporal catchment angle was positively correlated with central corneal power (R2 = 0.18; p = 0.02), peripheral corneal power (R2 = 0.18; p = 0.01), anterior chamber depth (R2 = 0.29; p = 0.002), and corneal diameter (R2 = 0.37; p = 0.002). Using multivariate linear regression analysis, we determined that central corneal power in the horizontal meridian and corneal diameter, in combination, best predicted the magnitude of the temporal catchment angle (R2 = 0.37; p = 0.0001). Conclusions. We have developed a reliable method of measuring the temporal catchment angle using a new head-mounted instrument. The temporal catchment angle was highly correlated with central corneal power and corneal diameter, in combination. The temporal catchment angle or its correlated ocular dimensions could be used to investigate risk factors for pterygia and cortical cataract.
AB - Purpose. When a beam of light is directed toward the temporal limbus from an angle of about 120° temporal to the primary line of sight, an illuminated patch appears on the sclera at the nasal limbus. An optical apparatus was developed for measuring the angular range of this optical phenomenon, often called the temporal catchment angle. It is possible that the temporal catchment angle or its correlates could serve as a key risk factor for the development of pterygia or cortical cataract. Methods. We built an apparatus that allows variation in the angle of a beam directed toward the temporal limbus. Two examiners measured the angular catchment range over which peripheral light focusing occurred for the right eyes of 30 subjects. Other anterior segment dimensions, including palpebral aperture height, refractive error, central and peripheral corneal power, anterior chamber depth, and corneal diameter, were measured. Results. There was no statistically or clinically significant difference between the repeated measures of the examiners. The mean temporal catchment angle was 17.1° (SD, 6.5). The intraobserver and interobserver 95% limits of agreement were 6.2 and 9.7°, respectively. The mean posterior limit was 121.0° (SD, 5.5), and the mean anterior limit was 104.1° (SD, 6.5) from the primary line of sight. The temporal catchment angle was positively correlated with central corneal power (R2 = 0.18; p = 0.02), peripheral corneal power (R2 = 0.18; p = 0.01), anterior chamber depth (R2 = 0.29; p = 0.002), and corneal diameter (R2 = 0.37; p = 0.002). Using multivariate linear regression analysis, we determined that central corneal power in the horizontal meridian and corneal diameter, in combination, best predicted the magnitude of the temporal catchment angle (R2 = 0.37; p = 0.0001). Conclusions. We have developed a reliable method of measuring the temporal catchment angle using a new head-mounted instrument. The temporal catchment angle was highly correlated with central corneal power and corneal diameter, in combination. The temporal catchment angle or its correlated ocular dimensions could be used to investigate risk factors for pterygia and cortical cataract.
KW - Cornea
KW - Peripheral light-focusing
KW - Pterygium
KW - Temporal catchment angle
KW - Ultraviolet radiation
UR - http://www.scopus.com/inward/record.url?scp=13844271473&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=13844271473&partnerID=8YFLogxK
U2 - 10.1097/01.OPX.0000153169.75212.1B
DO - 10.1097/01.OPX.0000153169.75212.1B
M3 - Article
C2 - 15711456
AN - SCOPUS:13844271473
SN - 1040-5488
VL - 82
SP - 94
EP - 100
JO - Optometry and Vision Science
JF - Optometry and Vision Science
IS - 2
ER -