Noise characteristics of U. S. synchrotron radiation sources

L. Powers

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

Noise characteristics of the U. S. x-ray synchrotron sources are compared in the 0-2.5-kHz region. In general, little difference is found in the characteristic frequencies of the noise on focused and unfocused beamlines of a particular source, but the magnitude and white-noise levels differ. The National Synchrotron Light Source shows the least characteristic noise and the noise that is observed is small in magnitude (2-3 times the white-noise level).

Original languageEnglish (US)
Pages (from-to)3024-3026
Number of pages3
JournalReview of Scientific Instruments
Volume57
Issue number12
DOIs
StatePublished - 1986

ASJC Scopus subject areas

  • Instrumentation

Fingerprint

Dive into the research topics of 'Noise characteristics of U. S. synchrotron radiation sources'. Together they form a unique fingerprint.