N2 - The methods used to concentrate enteric viruses from water have remained largely unchanged for nearly 30 years, with the most common technique being the use of 1MDS Virozorb filters followed by organic flocculation for secondary concentration. Recently, a few studies have investigated alternatives; however, many of these methods are impractical for use in the field or share some of the limitations of this traditional method. In the present study, the NanoCeram virus sampler, an electropositive pleated microporous filter composed of microglass filaments coated with nanoalumina fibers, was evaluated. Test viruses were first concentrated by passage of 20 liters of seeded water through the filter (average filter retention efficiency was >99.8%), and then the viruses were recovered using various salt-based or proteinaceous eluting solutions. A 1.0% sodium polyphosphate solution with 0.05 M glycine was determined to be the most effective. The recovered viruses were then further concentrated using Centricon Plus-70 centrifugal ultrafilters to a final volume of 3.3 (±0.3 [standard deviation]) ml; this volume compares quite favorably to that of previously described methods, such as organic flocculation (~15 to 40 ml). The overall virus recovery efficiencies were 66% for poliovirus 1, 83% for echovirus 1, 77% for coxsackievirus B5, 14% for adenovirus 2, and 56% for MS2 coliphage. In addition, this method appears to be compatible with both cell culture and PCR assays. This new approach for the recovery of viruses from water is therefore a viable alternative to currently used methods when small volumes of final concentrate are an advantage.
AB - The methods used to concentrate enteric viruses from water have remained largely unchanged for nearly 30 years, with the most common technique being the use of 1MDS Virozorb filters followed by organic flocculation for secondary concentration. Recently, a few studies have investigated alternatives; however, many of these methods are impractical for use in the field or share some of the limitations of this traditional method. In the present study, the NanoCeram virus sampler, an electropositive pleated microporous filter composed of microglass filaments coated with nanoalumina fibers, was evaluated. Test viruses were first concentrated by passage of 20 liters of seeded water through the filter (average filter retention efficiency was >99.8%), and then the viruses were recovered using various salt-based or proteinaceous eluting solutions. A 1.0% sodium polyphosphate solution with 0.05 M glycine was determined to be the most effective. The recovered viruses were then further concentrated using Centricon Plus-70 centrifugal ultrafilters to a final volume of 3.3 (±0.3 [standard deviation]) ml; this volume compares quite favorably to that of previously described methods, such as organic flocculation (~15 to 40 ml). The overall virus recovery efficiencies were 66% for poliovirus 1, 83% for echovirus 1, 77% for coxsackievirus B5, 14% for adenovirus 2, and 56% for MS2 coliphage. In addition, this method appears to be compatible with both cell culture and PCR assays. This new approach for the recovery of viruses from water is therefore a viable alternative to currently used methods when small volumes of final concentrate are an advantage.
UR - http://www.scopus.com/inward/record.url?scp=79958198742&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79958198742&partnerID=8YFLogxK
U2 - 10.1128/AEM.02705-10
DO - 10.1128/AEM.02705-10
M3 - Article
C2 - 21441329
AN - SCOPUS:79958198742
SN - 0099-2240
VL - 77
SP - 3500
EP - 3506
JO - Applied and environmental microbiology
JF - Applied and environmental microbiology
IS - 10
ER -