TY - JOUR
T1 - Microstructural evolution of low-dose separation by implanted oxygen materials implanted at 65 and 100 keV
AU - Jeoung, Jun Sik
AU - Anderson, Philip
AU - Seraphin, Supapan
N1 - Funding Information:
The authors would like to thank Professor L. McIn-tyre, Department of Physics, The University of Arizona for the RBS analysis, Dr. Benedict Johnson, Department of Materials Science and Engineering, the University of Missouri at Rolla, for valuable discussions, and Rachel Evans Research Experience as Undergraduate (REU) for her assistance in the defect density analysis. The author gratefully acknowledges Dr. Sung Gun Kang and Professor Dieter K. Schroder, Department of Electrical Engineering, Arizona State University, for electrical measurements. The work was supported by the National Science Foundation, Grant No. DMR 0072955, and the REU, Grant No. DMR 9820336.
PY - 2003/9
Y1 - 2003/9
N2 - Thin separation by implanted oxygen substrates are attractive candidates for low-power, low-voltage electronic devices and can be obtained by low-dose, low-energy oxygen-ion implantation. We report in this study a variation of the process parameters that have never been investigated before, particularly for implantation with a high current density implanter. Characterization of the sample sets by transmission electron microscopy, secondary ion mass spectroscopy (SIMS), and Rutherford backscattering spectrometry (RBS) shows an optimum dose of 3.0 to 3.5 × 1017 O+/cm2 at 100 keV for forming a continuous buried oxide (BOX) layer compared to 2.5 × 1017 O+/cm2 at 65 keV. At this optimum condition for 100 keV, the thickness of Si top layers and BOX layers is in the range of 175-185 nm and 70-80 nm, respectively. Analysis of the breakdown voltage of small area capacitors shows a breakdown field in the range of 6.0-7.0 MV/cm, which is adequate for low-power, low-voltage devices. SIMS analysis shows that the maximum oxygen concentration of as-implanted samples is located at depths of 160 and 240 nm for the implantation energy of 65 and 100 keV, respectively. A significant redistribution of oxygen occurs at temperatures above 1300°C during the ramping process. RBS analysis showed that a high-quality crystalline Si layer was produced after annealing at 1350°C for 4 h. The defect density determined by the chemical etching method was found to be very low (<300 defects per cm2) for all samples with a dose range of 3.0 × 1017 O+/cm2 to 6.0 × 1017 O+/cm2 implanted at 100 keV. However, a 65 keV sample with a dose of 4.5 × 1017 O+/cm2 contains about 109 defects per cm2. The larger defect density in the 65-keV sample may be due to the shift of oxygen depth distribution toward the surface, resulting in easier defect extension during the annealing process. The oxide precipitates in the Si overlayer play a key role in defect reduction by blocking the extension of dislocations to the surface.
AB - Thin separation by implanted oxygen substrates are attractive candidates for low-power, low-voltage electronic devices and can be obtained by low-dose, low-energy oxygen-ion implantation. We report in this study a variation of the process parameters that have never been investigated before, particularly for implantation with a high current density implanter. Characterization of the sample sets by transmission electron microscopy, secondary ion mass spectroscopy (SIMS), and Rutherford backscattering spectrometry (RBS) shows an optimum dose of 3.0 to 3.5 × 1017 O+/cm2 at 100 keV for forming a continuous buried oxide (BOX) layer compared to 2.5 × 1017 O+/cm2 at 65 keV. At this optimum condition for 100 keV, the thickness of Si top layers and BOX layers is in the range of 175-185 nm and 70-80 nm, respectively. Analysis of the breakdown voltage of small area capacitors shows a breakdown field in the range of 6.0-7.0 MV/cm, which is adequate for low-power, low-voltage devices. SIMS analysis shows that the maximum oxygen concentration of as-implanted samples is located at depths of 160 and 240 nm for the implantation energy of 65 and 100 keV, respectively. A significant redistribution of oxygen occurs at temperatures above 1300°C during the ramping process. RBS analysis showed that a high-quality crystalline Si layer was produced after annealing at 1350°C for 4 h. The defect density determined by the chemical etching method was found to be very low (<300 defects per cm2) for all samples with a dose range of 3.0 × 1017 O+/cm2 to 6.0 × 1017 O+/cm2 implanted at 100 keV. However, a 65 keV sample with a dose of 4.5 × 1017 O+/cm2 contains about 109 defects per cm2. The larger defect density in the 65-keV sample may be due to the shift of oxygen depth distribution toward the surface, resulting in easier defect extension during the annealing process. The oxide precipitates in the Si overlayer play a key role in defect reduction by blocking the extension of dislocations to the surface.
UR - http://www.scopus.com/inward/record.url?scp=0141593379&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0141593379&partnerID=8YFLogxK
U2 - 10.1557/JMR.2003.0304
DO - 10.1557/JMR.2003.0304
M3 - Article
AN - SCOPUS:0141593379
SN - 0884-2914
VL - 18
SP - 2177
EP - 2187
JO - Journal of Materials Research
JF - Journal of Materials Research
IS - 9
ER -