TY - JOUR
T1 - Measurement of near-normal concentrations of erythrocyte protoporphyrin with the hematofluorometer
T2 - Influence of plasma on 'front-surface illumination' assay
AU - Schifman, R. B.
AU - Finley, P. R.
PY - 1981
Y1 - 1981
N2 - Zinc protoporphyrin in erythrocytes increases in iron depletion. Because the hematofluorometer directly measures zinc protoporphyrin in whole blood, it may therefore be a useful screening instrument for detecting iron deficiency. We evaluated its performance with normal to slightly above-normal zinc protoporphyrin concentrations (0.2 to 2.0 mg/L) in erythrocytes, because this is a critical range for differentiating normal and iron-deficient individuals. There was excellent correlation (r2 = 0.900) between erythrocyte protoporphyrin as measured by an extraction procedure and as measured directly with the hematofluorometer. However, at these concentrations, plasma caused hematofluorometer readings to be spuriously high, by 2.4 to 89.4%, an effect due to the instrument's optical design. The effect can be eliminated by washing the cells free of plasma or by allowing erythrocytes to displace plasma by settling to the illuminated surface before the measurement. The interference does not affect the hematofluorometer's sensitivity, but abnormal results obtained for whole blood should be confirmed with more-specific tests, and interlaboratory precision may be influenced if whole-blood samples are used. A 1-min delay from sample placement to measurement decreased zinc protoporphyrin by 2.6 to 36.9%. We also describe the use of cryopreserved control erythrocytes, for which the CV is 2.3% for a concentration of 0.96 mg per liter of erythrocytes, which are not affected by time of measurement, and which are stable for three months.
AB - Zinc protoporphyrin in erythrocytes increases in iron depletion. Because the hematofluorometer directly measures zinc protoporphyrin in whole blood, it may therefore be a useful screening instrument for detecting iron deficiency. We evaluated its performance with normal to slightly above-normal zinc protoporphyrin concentrations (0.2 to 2.0 mg/L) in erythrocytes, because this is a critical range for differentiating normal and iron-deficient individuals. There was excellent correlation (r2 = 0.900) between erythrocyte protoporphyrin as measured by an extraction procedure and as measured directly with the hematofluorometer. However, at these concentrations, plasma caused hematofluorometer readings to be spuriously high, by 2.4 to 89.4%, an effect due to the instrument's optical design. The effect can be eliminated by washing the cells free of plasma or by allowing erythrocytes to displace plasma by settling to the illuminated surface before the measurement. The interference does not affect the hematofluorometer's sensitivity, but abnormal results obtained for whole blood should be confirmed with more-specific tests, and interlaboratory precision may be influenced if whole-blood samples are used. A 1-min delay from sample placement to measurement decreased zinc protoporphyrin by 2.6 to 36.9%. We also describe the use of cryopreserved control erythrocytes, for which the CV is 2.3% for a concentration of 0.96 mg per liter of erythrocytes, which are not affected by time of measurement, and which are stable for three months.
UR - http://www.scopus.com/inward/record.url?scp=0019379448&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0019379448&partnerID=8YFLogxK
U2 - 10.1093/clinchem/27.1.153
DO - 10.1093/clinchem/27.1.153
M3 - Article
C2 - 7449099
AN - SCOPUS:0019379448
SN - 0009-9147
VL - 27
SP - 153
EP - 156
JO - Clinical chemistry
JF - Clinical chemistry
IS - 1
ER -