T1 - Low uncertainty measurements of bidirectional reflectance factor on the NPOESS/VIIRS solar diffuser
AU - Lessel, Kristen
AU - McClain, Stephen
PY - 2007
Y1 - 2007
N2 - An illuminated Solar Diffuser is the calibration source for the VIS/NIR bands on the NPOESS/VIIRS sensor. We completed a set of BRF measurements to fully characterize the distribution of scattered light from the solar diffuser. NPOESS/VIIRS has an overall VIS/NIR radiometric calibration uncertainty requirement of 2%(1 sigma), of which 1.32% was allocated to the characterization of the BRF. In order to meet this requirement, we modified the existing goniometer and measurement procedure used on MODIS. Modifications include sample yoke redesign, periodic measurements of the lamp polarization coupled with stability measurements, modifications to source optics, and stray light reduction. We measured BRF in 6 spectral wavebands for 9 out-of-plane illumination angles and 2 view angles. We achieved NIST traceable measurements with an uncertainty ranging from 1.09% to 1.32%. Our measurements of a smaller Spectralon™ sample match NIST measurements of the same sample to better than 0.5%. These requirements are nominally the same as achieved on MODIS. As a result of instrument upgrades, we currently meet this overall uncertainty while having included additional uncertainty terms.
AB - An illuminated Solar Diffuser is the calibration source for the VIS/NIR bands on the NPOESS/VIIRS sensor. We completed a set of BRF measurements to fully characterize the distribution of scattered light from the solar diffuser. NPOESS/VIIRS has an overall VIS/NIR radiometric calibration uncertainty requirement of 2%(1 sigma), of which 1.32% was allocated to the characterization of the BRF. In order to meet this requirement, we modified the existing goniometer and measurement procedure used on MODIS. Modifications include sample yoke redesign, periodic measurements of the lamp polarization coupled with stability measurements, modifications to source optics, and stray light reduction. We measured BRF in 6 spectral wavebands for 9 out-of-plane illumination angles and 2 view angles. We achieved NIST traceable measurements with an uncertainty ranging from 1.09% to 1.32%. Our measurements of a smaller Spectralon™ sample match NIST measurements of the same sample to better than 0.5%. These requirements are nominally the same as achieved on MODIS. As a result of instrument upgrades, we currently meet this overall uncertainty while having included additional uncertainty terms.
UR - http://www.scopus.com/inward/record.url?scp=42149176674&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=42149176674&partnerID=8YFLogxK
U2 - 10.1117/12.753243
DO - 10.1117/12.753243
M3 - Conference contribution
AN - SCOPUS:42149176674
SN - 9780819468253
T3 - Proceedings of SPIE - The International Society for Optical Engineering
BT - Earth Observing Systems XII
T2 - Earth Observing Systems XII
Y2 - 26 August 2007 through 28 August 2007
ER -