TY - JOUR
T1 - Left Ventricular Assist Device-Associated Carbon Monoxide and Iron-Enhanced Hypercoagulation
T2 - Impact of Concurrent Disease
AU - Nielsen, Vance G.
AU - Sobieski, Michael A.
AU - Slaughter, Mark S.
N1 - Publisher Copyright:
© American Society of Artificial Internal Organs.
PY - 2015/7/21
Y1 - 2015/7/21
N2 - Left ventricular assist device (LVAD) therapy is associated with thrombophilia despite anticoagulation. Of interest, LVAD patients have increased carboxyhemoglobin, a measure of upregulated heme oxygenase (Hmox) activity that releases carbon monoxide (CO) and iron. Given that CO and iron enhance plasmatic coagulation, we determined if LVAD patients had hypercoagulability and decreased fibrinolytic vulnerability with measurable CO and iron-mediated effects. Blood samples were obtained a month or more after implantation of the LVAD. Thrombelastographic methods to assess coagulation kinetics, fibrinolytic kinetics, formation of carboxyhemefibrinogen, and iron-mediated enhancement of clot growth were utilized. Coagulation and fibrinolytic parameter normal individual (n = 30) plasma values were determined. Sixteen LVAD patients were studied. CO and iron enhancement of coagulation were observed in the majority of LVAD patients, contributing to hypercoagulation. However, most patients demonstrated abnormally increased rates of clot lysis. Critically, hemolysis as assessed by circulating lactate dehydrogenase activity was small in this cohort, and only four patients without comorbid states (e.g., obesity, diabetes, sleep apnea) were hypercoagulable with evidence of Hmox upregulation. However, seven patients with comorbidities were hypercoagulable with Hmox upregulation. Future investigation of CO and iron-related thrombophilia and comorbid disease is warranted to define its role in LVAD-related thrombosis.
AB - Left ventricular assist device (LVAD) therapy is associated with thrombophilia despite anticoagulation. Of interest, LVAD patients have increased carboxyhemoglobin, a measure of upregulated heme oxygenase (Hmox) activity that releases carbon monoxide (CO) and iron. Given that CO and iron enhance plasmatic coagulation, we determined if LVAD patients had hypercoagulability and decreased fibrinolytic vulnerability with measurable CO and iron-mediated effects. Blood samples were obtained a month or more after implantation of the LVAD. Thrombelastographic methods to assess coagulation kinetics, fibrinolytic kinetics, formation of carboxyhemefibrinogen, and iron-mediated enhancement of clot growth were utilized. Coagulation and fibrinolytic parameter normal individual (n = 30) plasma values were determined. Sixteen LVAD patients were studied. CO and iron enhancement of coagulation were observed in the majority of LVAD patients, contributing to hypercoagulation. However, most patients demonstrated abnormally increased rates of clot lysis. Critically, hemolysis as assessed by circulating lactate dehydrogenase activity was small in this cohort, and only four patients without comorbid states (e.g., obesity, diabetes, sleep apnea) were hypercoagulable with evidence of Hmox upregulation. However, seven patients with comorbidities were hypercoagulable with Hmox upregulation. Future investigation of CO and iron-related thrombophilia and comorbid disease is warranted to define its role in LVAD-related thrombosis.
KW - carbon monoxide
KW - iron
KW - left ventricular assist device
KW - thrombelastography
KW - thrombosis
UR - http://www.scopus.com/inward/record.url?scp=84937547986&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84937547986&partnerID=8YFLogxK
U2 - 10.1097/MAT.0000000000000210
DO - 10.1097/MAT.0000000000000210
M3 - Article
C2 - 25710774
AN - SCOPUS:84937547986
SN - 1058-2916
VL - 61
SP - 417
EP - 423
JO - ASAIO Journal
JF - ASAIO Journal
IS - 4
ER -