TY - GEN
T1 - Kinematics and dynamics comparison between three parallel robots for lower extremity rehabilitation
AU - Dabiri, Arman
AU - Sabet, Sahand
AU - Poursina, Mohammad
AU - Nikravesh, Parviz E.
AU - Armstrong, David G
N1 - Publisher Copyright:
© Copyright 2017 ASME.
PY - 2017
Y1 - 2017
N2 - Ulceration of the foot is one of the most common complications of diabetes mellitus and diabetes-related cause of hospitalization and lower extremity amputations. There have been proposed several treatments and utilized different devices to prevent or at least improve this. It has been shown physical therapy interventions are the most effective in the treatment of diabetic foot wounds among of all the proposed treatments, where a fully controlled motion in patients' foot is desired on a pure rotational trajectory. Therefore, parallel robots represent a good candidate for this rehabilitation purpose because of their high accuracy. This paper is devoted to designing optimal structures of three six-degree-of-freedom parallel robots (i.e. Stewart, HEXA, and INRIA Active Wrist) for the lower extremity rehabilitation by the use of the genetic algorithm and Monte Carlo method. For this purpose, several key designing parameters such as the size of the platform, the length of manipulators, actuators' parameters, and reachable workspace are considered. These designing parameters are optimized such that results in the best systems' kinematics and dynamics performance. Consequently, the advantages and disadvantages of each platform are discussed.
AB - Ulceration of the foot is one of the most common complications of diabetes mellitus and diabetes-related cause of hospitalization and lower extremity amputations. There have been proposed several treatments and utilized different devices to prevent or at least improve this. It has been shown physical therapy interventions are the most effective in the treatment of diabetic foot wounds among of all the proposed treatments, where a fully controlled motion in patients' foot is desired on a pure rotational trajectory. Therefore, parallel robots represent a good candidate for this rehabilitation purpose because of their high accuracy. This paper is devoted to designing optimal structures of three six-degree-of-freedom parallel robots (i.e. Stewart, HEXA, and INRIA Active Wrist) for the lower extremity rehabilitation by the use of the genetic algorithm and Monte Carlo method. For this purpose, several key designing parameters such as the size of the platform, the length of manipulators, actuators' parameters, and reachable workspace are considered. These designing parameters are optimized such that results in the best systems' kinematics and dynamics performance. Consequently, the advantages and disadvantages of each platform are discussed.
UR - http://www.scopus.com/inward/record.url?scp=85034750683&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85034750683&partnerID=8YFLogxK
U2 - 10.1115/DETC2017-68357
DO - 10.1115/DETC2017-68357
M3 - Conference contribution
AN - SCOPUS:85034750683
T3 - Proceedings of the ASME Design Engineering Technical Conference
BT - 13th International Conference on Multibody Systems, Nonlinear Dynamics, and Control
PB - American Society of Mechanical Engineers (ASME)
T2 - ASME 2017 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, IDETC/CIE 2017
Y2 - 6 August 2017 through 9 August 2017
ER -