T1 - Interferometric local measurements of high-order aberrations in progressive addition lenses
AU - Chamadoira, Sara
AU - Sasian, Jose M
AU - Acosta, Eva
N1 - Publisher Copyright:
Copyright © 2015 American Academy of Optometry.
PY - 2015/10/27
Y1 - 2015/10/27
N2 - Purpose. The main goal of this work is to show the principles, design, and performance of a modified point diffraction interferometer (PDI) for evaluating the local higher-order aberrations of progressive addition lenses (PALs). Because aberrations have different impacts in visual perception, we propose a device to provide a customized solution with the best permissible amounts and combinations of aberrations for improving a subject's vision. Methods. A PDI has been adapted to measure local high-order aberrations in PALs. Results. High-order aberrations in three different PALs within four relevant circular regions of interest (ROIs) with a radius ranging from 0.4 to 2.4 mm were measured with an accuracy of /10 within the ROI using the tailored PDI. The interferometer also allows for easily choosing the position and number of the ROIs. Conclusions. The interferometric device is compact, robust, and accurate. The operational principle is very simple, and it provides the local high-order aberrations directly without adding additional parts to the interferometer. As expected, the amount of high-order aberrations depends on the chosen ROI of the PAL; the corridor is the more critical region.We found, in accordance with the literature, that, in the corridor, second- and third-order aberrations are dominant and spherical aberration is negligible.
AB - Purpose. The main goal of this work is to show the principles, design, and performance of a modified point diffraction interferometer (PDI) for evaluating the local higher-order aberrations of progressive addition lenses (PALs). Because aberrations have different impacts in visual perception, we propose a device to provide a customized solution with the best permissible amounts and combinations of aberrations for improving a subject's vision. Methods. A PDI has been adapted to measure local high-order aberrations in PALs. Results. High-order aberrations in three different PALs within four relevant circular regions of interest (ROIs) with a radius ranging from 0.4 to 2.4 mm were measured with an accuracy of /10 within the ROI using the tailored PDI. The interferometer also allows for easily choosing the position and number of the ROIs. Conclusions. The interferometric device is compact, robust, and accurate. The operational principle is very simple, and it provides the local high-order aberrations directly without adding additional parts to the interferometer. As expected, the amount of high-order aberrations depends on the chosen ROI of the PAL; the corridor is the more critical region.We found, in accordance with the literature, that, in the corridor, second- and third-order aberrations are dominant and spherical aberration is negligible.
KW - Local high-order aberration
KW - Point diffraction interferometer
KW - Progressive addition lenses
UR - http://www.scopus.com/inward/record.url?scp=84946063105&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84946063105&partnerID=8YFLogxK
U2 - 10.1097/OPX.0000000000000708
DO - 10.1097/OPX.0000000000000708
M3 - Article
C2 - 26390351
AN - SCOPUS:84946063105
SN - 1040-5488
VL - 92
SP - 1047
EP - 1055
JO - Optometry and Vision Science
JF - Optometry and Vision Science
IS - 11
ER -