@inproceedings{d40e9a23a7f24c79bb6d59a8a1398f00,
title = "Interactions between UV and membrane filters during removal of bacteria and TOC from DI water",
abstract = "An important issue which has received very little attention in the design of deionized water polishing loops is the optimum sequencing of membrane filters with the UV treatment units. The primary objective of this paper was to investigate the interactions between UV 185 treatment and filtration through membranes. In general, the sequencing of various units in the polishing loop is an important factor in developing optimum strategies for toxic organic compound (TOC) removal. The results of this study indicate that under most conditions TOC can be removed more effectively if the filter is placed before the UV unit.",
author = "Farhang Shadman and Robert Governal and Alison Bonner",
year = "1990",
language = "English (US)",
isbn = "1877862002",
series = "Proceedings, Annual Technical Meeting - Institute of Environmental Sciences",
publisher = "Publ by Inst of Environmental Sciences",
pages = "221--223",
booktitle = "Proceedings, Annual Technical Meeting - Institute of Environmental Sciences",
note = "Proceedings of the 36th Annual Technical Meeting of the Institute of Environmental Sciences ; Conference date: 23-04-1990 Through 27-04-1990",
}