N2 - Objectives: To determine the feasibility of integrating pre-intubation ultrasound into airway course and assess emergency medicine (EM) residents’ confidence and comfort level in using ultrasound for pre-intubation hemodynamic stabilization and identifying cricothyroid membrane after the training session. Materials and methods: This is a retrospective study. Pre-intubation ultrasound training was delivered with the following ultrasound components (didactics and hands-on sessions using human models) to EM residents: (1) sonoanatomy and scanning technique to identify cricothyroid membrane and (2) pre-intubation echocardiography for recognition of acute right ventricular failure and pre-intubation hemodynamic stabilization. Results: A total of 56 EM residents participated in this study. Only 21% [95% confidence interval (CI), 10–31%] reported using ultrasound for pre-intubation hemodynamic stabilization. After the training session, 89% (95% CI, 81–97%) reported that ultrasound-based teaching increased their knowledge of pre-intubation hemodynamic stabilization compared with traditional teaching methods. On a scale of 1 (low) through 10 (high), the average comfort level for integrating ultrasound findings into medical decision making for pre-intubation hemodynamic stabilization was 6.8 (95% CI, 6.3–7.3). Seventy-nine percent (95% CI, 68–89%) reported that focused training in airway ultrasound is adequate to identify cricothyroid membrane. On a scale of 1 (low) through 10 (high), the average confidence level for identifying cricothyroid membrane using ultrasound was 6.6 (95% CI, 6.1–7.1). Conclusion: At our institution, we successfully integrated pre-intubation ultrasound into an airway course. Emergency medicine residents had a moderate level of comfort and confidence level using ultrasound for pre-intubation hemodynamic stabilization and identifying cricothyroid membrane after the training session.
AB - Objectives: To determine the feasibility of integrating pre-intubation ultrasound into airway course and assess emergency medicine (EM) residents’ confidence and comfort level in using ultrasound for pre-intubation hemodynamic stabilization and identifying cricothyroid membrane after the training session. Materials and methods: This is a retrospective study. Pre-intubation ultrasound training was delivered with the following ultrasound components (didactics and hands-on sessions using human models) to EM residents: (1) sonoanatomy and scanning technique to identify cricothyroid membrane and (2) pre-intubation echocardiography for recognition of acute right ventricular failure and pre-intubation hemodynamic stabilization. Results: A total of 56 EM residents participated in this study. Only 21% [95% confidence interval (CI), 10–31%] reported using ultrasound for pre-intubation hemodynamic stabilization. After the training session, 89% (95% CI, 81–97%) reported that ultrasound-based teaching increased their knowledge of pre-intubation hemodynamic stabilization compared with traditional teaching methods. On a scale of 1 (low) through 10 (high), the average comfort level for integrating ultrasound findings into medical decision making for pre-intubation hemodynamic stabilization was 6.8 (95% CI, 6.3–7.3). Seventy-nine percent (95% CI, 68–89%) reported that focused training in airway ultrasound is adequate to identify cricothyroid membrane. On a scale of 1 (low) through 10 (high), the average confidence level for identifying cricothyroid membrane using ultrasound was 6.6 (95% CI, 6.1–7.1). Conclusion: At our institution, we successfully integrated pre-intubation ultrasound into an airway course. Emergency medicine residents had a moderate level of comfort and confidence level using ultrasound for pre-intubation hemodynamic stabilization and identifying cricothyroid membrane after the training session.
KW - Airway
KW - Cricothyroid membrane
KW - Echocardiography
KW - Emergency medicine
KW - Hemodynamic
KW - Pre-intubation
KW - Ultrasound
UR - http://www.scopus.com/inward/record.url?scp=85089005310&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85089005310&partnerID=8YFLogxK
U2 - 10.5005/jp-journals-10071-23370
DO - 10.5005/jp-journals-10071-23370
M3 - Article
AN - SCOPUS:85089005310
SN - 0972-5229
VL - 24
SP - 179
EP - 183
JO - Indian Journal of Critical Care Medicine
JF - Indian Journal of Critical Care Medicine
IS - 3
ER -