High luminance monochrome vs low luminance monochrome and color softcopy displays: Observer performance and visual search efficiency

Elizabeth A. Krupinski, Hans Roehrig, Jiahua Fan, Takahiro Yoneda

Research output: Chapter in Book/Report/Conference proceedingConference contribution

6 Scopus citations

Abstract

This study evaluated the potential clinical utility of a high-performance (3 Mega-pixel) color display compared with two monochrome displays - one of comparable luminance (250 cd/m 2) and one of higher luminance (450 cd/m 2). Six radiologists viewed 50 DR chest images, half with nodules and half without, once on each display. Eye position was recorded on a subset of images. There was no statistically significant difference in ROC Az performance as a function of monitor (F = 1.176, p = 0.3127), although there was a clear trend towards the monochrome 450 cd/m 2 monitor being better than the monochrome 250 cd/m 2 monitor, which was better than the color monitor. In terms of total viewing time, there were no statistically significant differences between the three monitors (F = 1.478, p = 0.2298). The dwell times associated with true and false positive decisions were shortest for the high luminance monochrome display, longer for the low luminance monochrome, and longest for the low luminance color display. Dwells for the false negative decisions were longest for the high luminance monochrome display, shorter for the low luminance monochrome, and shortest for the low luminance color display. The true negative dwells were not significantly different. The study suggest high luminance displays may have an advantage in terms of diagnostic accuracy and visual search efficiency for detecting nodules in chest images compared to both monochrome and color lower luminance displays, although these differences may have little clinical impact because they are relatively small.

Original languageEnglish (US)
Title of host publicationMedical Imaging 2007
Subtitle of host publicationImage Perception, Observer Performance, and Technology Assessment
DOIs
StatePublished - 2007
Externally publishedYes
EventMedical Imaging 2007: Image Perception, Observer Performance, and Technology Assessment - San Diego, CA, United States
Duration: Feb 21 2007Feb 22 2007

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume6515
ISSN (Print)1605-7422

Other

OtherMedical Imaging 2007: Image Perception, Observer Performance, and Technology Assessment
Country/TerritoryUnited States
CitySan Diego, CA
Period2/21/072/22/07

Keywords

  • Diagnostic accuracy
  • Luminance
  • Monitor color
  • Visual search

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Atomic and Molecular Physics, and Optics
  • Radiology Nuclear Medicine and imaging
  • Biomaterials

Fingerprint

Dive into the research topics of 'High luminance monochrome vs low luminance monochrome and color softcopy displays: Observer performance and visual search efficiency'. Together they form a unique fingerprint.

Cite this