N2 - Objectives: Discuss use of a linear incision for placement of a magnetically coupled bone anchored hearing implant. Methods: Case series. Results: Two patients underwent placement of magnetically coupled bone-anchored hearing implants (BAHI) through linear incisions. The first, a 40-year-old female with congenital single-sided deafness, previously had successful implantation of a percutaneous bone anchored hearing implant through a linear incision; unfortunately, she developed pain and intermittent drainage at her abutment site with time, resulting in a request for removal of her device. As an alternative to complete removal, we offered to replace the percutaneous implant with a magnetically coupled BAHI, employing the same linear incision previously. The second patient, a 53-year-old obese female with limited neck mobility and mixed hearing loss, underwent primary placement of a magnetically coupled BAHI through a linear incision. Limitations in neck mobility and patient body habitus precluded use of a traditional C-shaped incision. Both patients underwent surgery successfully, healed without incident, had their devices activated 6 weeks after their procedures, and are able to wear their implants more than 8 hours per day without discomfort. Conclusion: Surgical techniques for bone-anchored implants continue to evolve. Though manufacturers of magnetically coupled devices recommend using C-shaped incisions with large skin flaps, our first reported cases suggest that a small linear incision immediately overlying the implant magnet may be an acceptable alternative. Potential benefits include a smaller incision, less hair removal, smaller flap, decreased surgical time, and less postoperative pain.
AB - Objectives: Discuss use of a linear incision for placement of a magnetically coupled bone anchored hearing implant. Methods: Case series. Results: Two patients underwent placement of magnetically coupled bone-anchored hearing implants (BAHI) through linear incisions. The first, a 40-year-old female with congenital single-sided deafness, previously had successful implantation of a percutaneous bone anchored hearing implant through a linear incision; unfortunately, she developed pain and intermittent drainage at her abutment site with time, resulting in a request for removal of her device. As an alternative to complete removal, we offered to replace the percutaneous implant with a magnetically coupled BAHI, employing the same linear incision previously. The second patient, a 53-year-old obese female with limited neck mobility and mixed hearing loss, underwent primary placement of a magnetically coupled BAHI through a linear incision. Limitations in neck mobility and patient body habitus precluded use of a traditional C-shaped incision. Both patients underwent surgery successfully, healed without incident, had their devices activated 6 weeks after their procedures, and are able to wear their implants more than 8 hours per day without discomfort. Conclusion: Surgical techniques for bone-anchored implants continue to evolve. Though manufacturers of magnetically coupled devices recommend using C-shaped incisions with large skin flaps, our first reported cases suggest that a small linear incision immediately overlying the implant magnet may be an acceptable alternative. Potential benefits include a smaller incision, less hair removal, smaller flap, decreased surgical time, and less postoperative pain.
KW - BAHA
KW - Bone anchored hearing implant
KW - Magnetically coupled device
KW - Osteointegrating device
UR - http://www.scopus.com/inward/record.url?scp=85010193008&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85010193008&partnerID=8YFLogxK
U2 - 10.1097/MAO.0000000000001290
DO - 10.1097/MAO.0000000000001290
M3 - Article
C2 - 28068302
AN - SCOPUS:85010193008
SN - 1531-7129
VL - 38
SP - 221
EP - 224
JO - Otology and Neurotology
JF - Otology and Neurotology
IS - 2
ER -