Abstract
To evaluate the feasibility of implementing a pulse oximetry screening protocol at a city of mild elevation with a specific focus on the false-positive screening rate. Pulse oximetry screening was performed according to the proposed guidelines endorsed by the American Academy of Pediatrics at a center in Tucson, AZ, at an elevation of 2,643 ft (806 m). During a 10-month period in 2012, 1069 full-term asymptomatic newborns were screened ≥24 h after birth. The mean preductal oxygen saturation was 98.5 ± 1.3 % (range 92-100 %), and the mean postductal oxygen saturation was 98.6 ± 1.3 % (range 94-100 %). Of 1,069 patients screened, 7 were excluded secondary to protocol violations, and 1 screened positive. An echocardiogram was performed on the newborn with the positive screen, and it was normal with the exception of right-to-left shunting across a patent foramen ovale. The false-positive rate was 1/1,062 or 0.094 %. The pulse oximetry screening guidelines recommended by the American Academy of Pediatrics are feasible at an elevation of 2,643 ft (806 m) with a low false-positive rate. Adjustments to the protocol are not required for centers at elevations ≤2,643 ft. Future studies at greater elevations are warranted.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 1803-1807 |
| Number of pages | 5 |
| Journal | Pediatric Cardiology |
| Volume | 34 |
| Issue number | 8 |
| DOIs | |
| State | Published - Dec 2013 |
Keywords
- Altitude
- Critical congenital heart disease
- Newborn
- Pulse oximetry
ASJC Scopus subject areas
- Pediatrics, Perinatology, and Child Health
- Cardiology and Cardiovascular Medicine