TY - JOUR
T1 - Endoscope-tip interferometer for ultrahigh resolution frequency domain optical coherence tomography in mouse colon
AU - Tumlinson, Alexandre R.
AU - Barton, Jennifer K.
AU - Považay, Boris
AU - Sattman, Harald
AU - Unterhuber, Angelika
AU - Leitgeb, Rainer A.
AU - Drexler, Wolfgang
PY - 2006/3
Y1 - 2006/3
N2 - Frequency domain optical coherence tomography (FD-OCT) allows interferometer topologies with simplified system construction and handling. Problems of dispersion and polarization matching between the sample and reference arms, as well as beamsplitter spectral non-uniformity, are mitigated when the interferometer is wholly contained in the endoscope tip. A common path set-up, using a reference reflection originating from the inside surface of the glass envelope at the distal end of the endoscope, and an alternative approach with more efficient collection of the reference light using a novel beamsplitter design have been developed. High-speed (20,000 A-lines/s) ultrahigh axial resolution (2.4 μm) tomograms of mouse colon have been acquired using a 2 mm outer diameter endoscope in vivo. The FD-OCT system uses a compact mode-locked Ti:Al2O3 laser emitting a broad spectrum (160 nm full-width-half-maximum) centered at 800 nm in combination with a CCD based, spectrally sensitive detector.
AB - Frequency domain optical coherence tomography (FD-OCT) allows interferometer topologies with simplified system construction and handling. Problems of dispersion and polarization matching between the sample and reference arms, as well as beamsplitter spectral non-uniformity, are mitigated when the interferometer is wholly contained in the endoscope tip. A common path set-up, using a reference reflection originating from the inside surface of the glass envelope at the distal end of the endoscope, and an alternative approach with more efficient collection of the reference light using a novel beamsplitter design have been developed. High-speed (20,000 A-lines/s) ultrahigh axial resolution (2.4 μm) tomograms of mouse colon have been acquired using a 2 mm outer diameter endoscope in vivo. The FD-OCT system uses a compact mode-locked Ti:Al2O3 laser emitting a broad spectrum (160 nm full-width-half-maximum) centered at 800 nm in combination with a CCD based, spectrally sensitive detector.
UR - http://www.scopus.com/inward/record.url?scp=33644746298&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33644746298&partnerID=8YFLogxK
U2 - 10.1364/OE.14.001878
DO - 10.1364/OE.14.001878
M3 - Article
C2 - 19503517
AN - SCOPUS:33644746298
SN - 1094-4087
VL - 14
SP - 1878
EP - 1887
JO - Optics Express
JF - Optics Express
IS - 5
ER -