TY - JOUR
T1 - Effectiveness of UV-C equipped vacuum at reducing culturable surface-bound microorganisms on carpets
AU - Lutz, Eric A.
AU - Sharma, Smita
AU - Casto, Bruce
AU - Needham, Glen
AU - Buckley, Timothy J.
PY - 2010/12/15
Y1 - 2010/12/15
N2 - Carpets are both sinks and sources for exposure to chemicals, allergens, and microbes and consequently influence health, including asthma, allergies, and infectious diseases. Asthmatics, children, and the immune-compromised are particularly vulnerable to health risks resulting from exposure to carpet contaminants. To address this risk, a commercial upright vacuum cleaner with an ultraviolet germicidal lamp (λ=253.7 nm, UVC) has been developed for residential and commercial uses. However, its effectiveness in reducing microbial load on real-world carpets has not been previously demonstrated. Accordingly, the purpose of the current study was to evaluate the effectiveness of a UVC-equipped vacuum in reducing the carpet surface-bound microbial load. This was accomplished by comparing the carpet microbial surface load from pre- to post-treatment of 9 ft2 in-use carpet sections under three treatment scenarios: 1) UVC alone (UV), 2) the beater-bar plus vacuum (BB+Vac), or 3) a combination of all three (COMB). Each treatment was two minutes in duration. Microbial surface loads were measured by pressing contact plates containing Sabourauds Dextrose agar onto the carpet surface. In-use carpets from three locations were tested in place. The treatment effect was evaluated at two levels. First, we considered the mean reduction in CFU from pre- to post-treatment for each 9 ft2 carpet grid (n = 4 for each treatment). The second level considered each 1 ft2 section using a paired analysis (n = 40 to 49 for each treatment). A total of 125 pre/post-sample pairs were collected across the three treatments. Results showed that all three treatments were associated with a reduction in carpet microbial load (p < 0.0001). The COMB yielded the largest reduction of 13 CFU/plate (87% reduction) and was approximately the sum of the individual effects of either UVC (6.6 CFU/plate, 60% reduction, p = 0.009) or BB+Vac (7.3 CFU/plate, 78% reduction, p < 0.0001). We therefore conclude that a UVC-equipped vacuum approximately doubles the unit's effectiveness in reducing surface-bound microbial load, thereby holding promise as a means for decreasing indoor infectious disease risk.
AB - Carpets are both sinks and sources for exposure to chemicals, allergens, and microbes and consequently influence health, including asthma, allergies, and infectious diseases. Asthmatics, children, and the immune-compromised are particularly vulnerable to health risks resulting from exposure to carpet contaminants. To address this risk, a commercial upright vacuum cleaner with an ultraviolet germicidal lamp (λ=253.7 nm, UVC) has been developed for residential and commercial uses. However, its effectiveness in reducing microbial load on real-world carpets has not been previously demonstrated. Accordingly, the purpose of the current study was to evaluate the effectiveness of a UVC-equipped vacuum in reducing the carpet surface-bound microbial load. This was accomplished by comparing the carpet microbial surface load from pre- to post-treatment of 9 ft2 in-use carpet sections under three treatment scenarios: 1) UVC alone (UV), 2) the beater-bar plus vacuum (BB+Vac), or 3) a combination of all three (COMB). Each treatment was two minutes in duration. Microbial surface loads were measured by pressing contact plates containing Sabourauds Dextrose agar onto the carpet surface. In-use carpets from three locations were tested in place. The treatment effect was evaluated at two levels. First, we considered the mean reduction in CFU from pre- to post-treatment for each 9 ft2 carpet grid (n = 4 for each treatment). The second level considered each 1 ft2 section using a paired analysis (n = 40 to 49 for each treatment). A total of 125 pre/post-sample pairs were collected across the three treatments. Results showed that all three treatments were associated with a reduction in carpet microbial load (p < 0.0001). The COMB yielded the largest reduction of 13 CFU/plate (87% reduction) and was approximately the sum of the individual effects of either UVC (6.6 CFU/plate, 60% reduction, p = 0.009) or BB+Vac (7.3 CFU/plate, 78% reduction, p < 0.0001). We therefore conclude that a UVC-equipped vacuum approximately doubles the unit's effectiveness in reducing surface-bound microbial load, thereby holding promise as a means for decreasing indoor infectious disease risk.
UR - http://www.scopus.com/inward/record.url?scp=78650263920&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=78650263920&partnerID=8YFLogxK
U2 - 10.1021/es1015982
DO - 10.1021/es1015982
M3 - Article
C2 - 21033658
AN - SCOPUS:78650263920
SN - 0013-936X
VL - 44
SP - 9451
EP - 9455
JO - Environmental Science and Technology
JF - Environmental Science and Technology
IS - 24
ER -