TY - JOUR
T1 - Effectiveness evaluation of existing noise controls in a deep shaft underground mine
AU - Lutz, Eric A
AU - Reed, Rustin J.
AU - Turner, Dylan
AU - Littau, Sally R.
AU - Lee, Vivien
AU - Hu, Chengcheng
N1 - Publisher Copyright:
Copyright © 2015 JOEH, LLC.
PY - 2015/5/4
Y1 - 2015/5/4
N2 - Noise exposures and hearing loss in the mining industry continue to be a major problem, despite advances in noise control technologies. This study evaluated the effectiveness of engineering, administrative, and personal noise controls using both traditional and in-ear dosimetry by job task, work shift, and five types of earplug. The noise exposures of 22 miners performing deep shaft-sinking tasks were evaluated during 56 rotating shifts in an underground mine. Miners were earplug-insertion trained, earplug fit-tested, and monitored utilizing traditional and in-ear dosimetry. The mean TWA8 noise exposure via traditional dosimetry was 90.1 ± 8.2 dBA, while the mean in-ear TWA8 was 79.6 ± 13.8 dBA. The latter was significantly lower (p < 0.05) than the Mine Safety and Health Administration (MSHA) personal exposure limit (PEL) of 90 dBA. Dosimetry mean TWA8 noise exposures for bench blowing (103.5 ± 0.9 dBA), jumbo drill operation (103.0 ± 0.8 dBA), and mucking tasks (99.6 ± 4.7 dBA) were significantly higher (p < 0.05) than other tasks. For bench blowing, cable pulling, grinding, and jumbo drill operation tasks, the mean in-ear TWA8 was greater than 85 dBA. Those working swing shift had a significantly higher (p < 0.001) mean TWA8 noise exposure (95.4 ± 7.3 dBA) than those working day shift. For percent difference between traditional vs. in-ear dosimetry, there was no significant difference among types of earplug used. Reflective of occupational hearing loss rate trends across the mining industry, this study found that, despite existing engineering and administrative controls, noise exposure levels exceeded regulatory limits, while the addition of personal hearing protection limited excessive exposures.
AB - Noise exposures and hearing loss in the mining industry continue to be a major problem, despite advances in noise control technologies. This study evaluated the effectiveness of engineering, administrative, and personal noise controls using both traditional and in-ear dosimetry by job task, work shift, and five types of earplug. The noise exposures of 22 miners performing deep shaft-sinking tasks were evaluated during 56 rotating shifts in an underground mine. Miners were earplug-insertion trained, earplug fit-tested, and monitored utilizing traditional and in-ear dosimetry. The mean TWA8 noise exposure via traditional dosimetry was 90.1 ± 8.2 dBA, while the mean in-ear TWA8 was 79.6 ± 13.8 dBA. The latter was significantly lower (p < 0.05) than the Mine Safety and Health Administration (MSHA) personal exposure limit (PEL) of 90 dBA. Dosimetry mean TWA8 noise exposures for bench blowing (103.5 ± 0.9 dBA), jumbo drill operation (103.0 ± 0.8 dBA), and mucking tasks (99.6 ± 4.7 dBA) were significantly higher (p < 0.05) than other tasks. For bench blowing, cable pulling, grinding, and jumbo drill operation tasks, the mean in-ear TWA8 was greater than 85 dBA. Those working swing shift had a significantly higher (p < 0.001) mean TWA8 noise exposure (95.4 ± 7.3 dBA) than those working day shift. For percent difference between traditional vs. in-ear dosimetry, there was no significant difference among types of earplug used. Reflective of occupational hearing loss rate trends across the mining industry, this study found that, despite existing engineering and administrative controls, noise exposure levels exceeded regulatory limits, while the addition of personal hearing protection limited excessive exposures.
KW - mining
KW - noise
KW - noise controls
KW - noise exposures
KW - underground mining
UR - https://www.scopus.com/pages/publications/84928632811
UR - https://www.scopus.com/inward/citedby.url?scp=84928632811&partnerID=8YFLogxK
U2 - 10.1080/15459624.2014.987385
DO - 10.1080/15459624.2014.987385
M3 - Article
C2 - 25830445
AN - SCOPUS:84928632811
SN - 1545-9624
VL - 12
SP - 287
EP - 293
JO - Journal of occupational and environmental hygiene
JF - Journal of occupational and environmental hygiene
IS - 5
ER -