Effect of Arrival of Prior Mammograms on Recall Negation for Screening Mammograms Performed With Digital Breast Tomosynthesis in a Clinical Setting

Lara A. Hardesty, Kimberly E. Lind, Eric J. Gutierrez

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Purpose: This retrospective study evaluates the effect of comparison with prior mammograms on recall negation for screening mammography performed with digital breast tomosynthesis (DBT) in a clinical setting and compares it with that performed without DBT. Methods: This is an Institutional Review Board–approved, HIPAA-compliant retrospective review of the electronic medical record for all nonbaseline screening mammograms performed in clinical practice over 13 months. For each mammogram, we recorded if DBT were used, the BI-RADS assigned at initial interpretation, and whether prior mammograms were available at initial interpretation. If prior mammograms arrived later for comparison, the final BI-RADS assigned after comparison was recorded. A mammogram assigned a BI-RADS 0 at initial interpretation and assigned a BI-RADS 1 or BI-RADS 2 after prior mammograms arrived for comparison was labeled as a recall that was negated by the arrival of prior mammograms. The number of recalls negated for mammograms that used DBT was compared with that for mammograms that did not use DBT. Results: Arrival of prior mammograms for comparison negated the need for recall for mammograms performed with DBT by 67.67% and negated the need for recall for mammograms performed without DBT by 55.80%. After adjusting for age, density, and time between mammograms, the percentage of recalls negated by comparison with prior mammograms was not significantly different for mammograms performed with DBT than it was for those performed without DBT. Conclusion: Comparison with prior mammograms remains important for the minimization of recall rates during the use of DBT for screening mammography in the clinical setting.

Original languageEnglish (US)
Pages (from-to)1293-1299
Number of pages7
JournalJournal of the American College of Radiology
Volume15
Issue number9
DOIs
StatePublished - Sep 2018
Externally publishedYes

Keywords

  • comparison with prior mammograms
  • Digital breast tomosynthesis
  • recall rates
  • screening mammography

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Effect of Arrival of Prior Mammograms on Recall Negation for Screening Mammograms Performed With Digital Breast Tomosynthesis in a Clinical Setting'. Together they form a unique fingerprint.

Cite this