TY - JOUR
T1 - Distinguishing wet from dry age-related macular degeneration using three-dimensional computer-automated threshold Amsler grid testing
AU - Robison, Craig D.
AU - Jivrajka, Renu V.
AU - Bababeygy, Simon R.
AU - Fink, Wolfgang
AU - Sadun, Alfredo A.
AU - Sebag, J.
PY - 2011/10
Y1 - 2011/10
N2 - Background/aims: With the increased efficacy of current therapy for wet age-related macular degeneration (AMD), better ways to detect wet AMD are needed. This study was designed to test the ability of threedimensional contrast threshold Amsler grid (3D-CTAG) testing to distinguish wet AMD from dry AMD. Methods: Conventional paper Amsler grid and 3D-CTAG tests were performed in 90 eyes: 63 with AMD (34 dry, 29 wet) and 27 controls. Qualitative comparisons were based upon the three-dimensional shapes of central visual field (VF) defects. Quantitative analyses considered the number and volume of the three-dimensional defects. Results: 25/34 (74%) dry AMD and 6/29 (21%) wet AMD eyes had no distortions on paper Amsler grid. Of these, 5/25 (20%) dry and 6/6 (100%) wet (p=0.03) AMD eyes exhibited central VF defects with 3D-CTAG. Wet AMD displayed stepped defects in 16/28 (57%) eyes, compared with only 2/34 (6%) of dry AMD eyes (p=0.002). All three volumetric indices of VF defects were two- to four-fold greater in wet than dry AMD (p<0.006). 3D-CTAG had 83.9% positive and 90.6% negative predictive values for wet AMD. Conclusions: 3D-CTAG has a higher likelihood of detecting central VF defects than conventional Amsler grid, especially in wet AMD. Wet AMD can be distinguished from dry AMD by qualitative and quantitative 3D-CTAG criteria. Thus, 3D-CTAG may be useful in screening for wet AMD, quantitating disease severity, and providing a quantitative outcome measure of therapy.
AB - Background/aims: With the increased efficacy of current therapy for wet age-related macular degeneration (AMD), better ways to detect wet AMD are needed. This study was designed to test the ability of threedimensional contrast threshold Amsler grid (3D-CTAG) testing to distinguish wet AMD from dry AMD. Methods: Conventional paper Amsler grid and 3D-CTAG tests were performed in 90 eyes: 63 with AMD (34 dry, 29 wet) and 27 controls. Qualitative comparisons were based upon the three-dimensional shapes of central visual field (VF) defects. Quantitative analyses considered the number and volume of the three-dimensional defects. Results: 25/34 (74%) dry AMD and 6/29 (21%) wet AMD eyes had no distortions on paper Amsler grid. Of these, 5/25 (20%) dry and 6/6 (100%) wet (p=0.03) AMD eyes exhibited central VF defects with 3D-CTAG. Wet AMD displayed stepped defects in 16/28 (57%) eyes, compared with only 2/34 (6%) of dry AMD eyes (p=0.002). All three volumetric indices of VF defects were two- to four-fold greater in wet than dry AMD (p<0.006). 3D-CTAG had 83.9% positive and 90.6% negative predictive values for wet AMD. Conclusions: 3D-CTAG has a higher likelihood of detecting central VF defects than conventional Amsler grid, especially in wet AMD. Wet AMD can be distinguished from dry AMD by qualitative and quantitative 3D-CTAG criteria. Thus, 3D-CTAG may be useful in screening for wet AMD, quantitating disease severity, and providing a quantitative outcome measure of therapy.
UR - http://www.scopus.com/inward/record.url?scp=80053228797&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=80053228797&partnerID=8YFLogxK
U2 - 10.1136/bjo.2010.194886
DO - 10.1136/bjo.2010.194886
M3 - Article
C2 - 21270434
AN - SCOPUS:80053228797
SN - 0007-1161
VL - 95
SP - 1419
EP - 1423
JO - British Journal of Ophthalmology
JF - British Journal of Ophthalmology
IS - 10
ER -