Skip to main navigation Skip to search Skip to main content

Differences in Outflow Facility between Angiographically Identified High- Versus Low-Flow Regions of the Conventional Outflow Pathways in Porcine Eyes

  • Clemens A. Strohmaier
  • , Fiona S. McDonnell
  • , Xiaowei Zhang
  • , Daniel Wanderer
  • , W. Daniel Stamer
  • , Robert N. Weinreb
  • , Alex S. Huang

Research output: Contribution to journalArticlepeer-review

Abstract

PURPOSE. To investigate differences in outflow facility between angiographically determined high- and low-flow segments of the conventional outflow pathway in porcine eyes. METHODS. Porcine anterior segments (n = 14) were mounted in a perfusion chamber and perfused using Dulbecco's phosphate buffered solution with glucose. Fluorescein angiography was performed to determine high- and low-flow regions of the conventional outflow pathways. The trabecular meshwork (TM) was occluded using cyanoacrylate glue, except for residual 5-mm TM areas that were either high or low flow at baseline, designating these eyes as "residual high-flow"or "residual low-flow"eyes. Subsequently, outflow was quantitatively reassessed and compared between residual high-flow and residual low-flow eyes followed by indocyanine green angiography. RESULTS. Fluorescein aqueous angiography demonstrated high-flow and low-flow regions. Baseline outflow facilities were 0.320 ± 0.08 and 0.328 ± 0.10 μL/min/mmHg (P = 0.676) in residual high-flow and residual low-flow eyes before TM occlusion, respectively. After partial trabecular meshwork occlusion, outflow facility decreased to 0.209 ± 0.07 μL/min/mmHg (-32.66% ± 19.53%) and 0.114 ± 0.08 μL/min/mmHg (-66.57% ± 23.08%) in residual high- and low-flow eyes (P = 0.035), respectively. There was a significant difference in the resulting IOP increase (P = 0.034). CONCLUSIONS. Angiographically determined high- and low-flow regions in the conventional outflow pathways differ in their segmental outflow facility; thus, there is an uneven distribution of local outflow facility across different parts of the TM.

Original languageEnglish (US)
Article number29
JournalInvestigative Ophthalmology and Visual Science
Volume64
Issue number3
DOIs
StatePublished - Mar 2023
Externally publishedYes

Keywords

  • Aqueous angiography
  • aqueous humor outflow
  • trabecular meshwork

ASJC Scopus subject areas

  • Ophthalmology
  • Sensory Systems
  • Cellular and Molecular Neuroscience

Fingerprint

Dive into the research topics of 'Differences in Outflow Facility between Angiographically Identified High- Versus Low-Flow Regions of the Conventional Outflow Pathways in Porcine Eyes'. Together they form a unique fingerprint.

Cite this