TY - JOUR
T1 - Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position
AU - Eom, Youngsub
AU - Ryu, Dongok
AU - Kim, Dae Wook
AU - Yang, Seul Ki
AU - Song, Jong Suk
AU - Kim, Sug Whan
AU - Kim, Hyo Myung
N1 - Funding Information:
This study was supported in part by the SRC program (2010-0027910) of the Center for Galaxy Evolution Research (CGER), by the Korea Astronomy and Space Science Institute under the R&D program (Project No. 2014-9-710-03) supervised by the Ministry of Science, ICT and Future Planning, South Korea, and by the Busan Sungmo Eye Hospital Sodam Scholarship Committee, Busan, South Korea. The sponsor had no role in the design or conduct of this research.
Publisher Copyright:
© 2016, Springer-Verlag Berlin Heidelberg.
PY - 2016/10/1
Y1 - 2016/10/1
N2 - Background: To evaluate the toric intraocular lens (IOL) calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position (ELP). Methods: Two thousand samples of corneal parameters with keratometric astigmatism ≥ 1.0 D were obtained using bootstrap methods. The probability distributions for incision-induced keratometric and posterior corneal astigmatisms, as well as ELP were estimated from the literature review. The predicted residual astigmatism error using method D with an IOL add power calculator (IAPC) was compared with those derived using methods A, B, and C through Monte-Carlo simulation. Method A considered the keratometric astigmatism and incision-induced keratometric astigmatism, method B considered posterior corneal astigmatism in addition to the A method, method C considered incision-induced posterior corneal astigmatism in addition to the B method, and method D considered ELP in addition to the C method. To verify the IAPC used in this study, the predicted toric IOL cylinder power and its axis using the IAPC were compared with ray-tracing simulation results. Results: The median magnitude of the predicted residual astigmatism error using method D (0.25 diopters [D]) was smaller than that derived using methods A (0.42 D), B (0.38 D), and C (0.28 D) respectively. Linear regression analysis indicated that the predicted toric IOL cylinder power and its axis had excellent goodness-of-fit between the IAPC and ray-tracing simulation. Conclusions: The IAPC is a simple but accurate method for predicting the toric IOL cylinder power and its axis considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and ELP.
AB - Background: To evaluate the toric intraocular lens (IOL) calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position (ELP). Methods: Two thousand samples of corneal parameters with keratometric astigmatism ≥ 1.0 D were obtained using bootstrap methods. The probability distributions for incision-induced keratometric and posterior corneal astigmatisms, as well as ELP were estimated from the literature review. The predicted residual astigmatism error using method D with an IOL add power calculator (IAPC) was compared with those derived using methods A, B, and C through Monte-Carlo simulation. Method A considered the keratometric astigmatism and incision-induced keratometric astigmatism, method B considered posterior corneal astigmatism in addition to the A method, method C considered incision-induced posterior corneal astigmatism in addition to the B method, and method D considered ELP in addition to the C method. To verify the IAPC used in this study, the predicted toric IOL cylinder power and its axis using the IAPC were compared with ray-tracing simulation results. Results: The median magnitude of the predicted residual astigmatism error using method D (0.25 diopters [D]) was smaller than that derived using methods A (0.42 D), B (0.38 D), and C (0.28 D) respectively. Linear regression analysis indicated that the predicted toric IOL cylinder power and its axis had excellent goodness-of-fit between the IAPC and ray-tracing simulation. Conclusions: The IAPC is a simple but accurate method for predicting the toric IOL cylinder power and its axis considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and ELP.
KW - Effective lens position
KW - Posterior corneal astigmatism, Incision-induced astigmatism
KW - Toric intraocular lens
UR - http://www.scopus.com/inward/record.url?scp=84982281653&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84982281653&partnerID=8YFLogxK
U2 - 10.1007/s00417-016-3446-3
DO - 10.1007/s00417-016-3446-3
M3 - Article
C2 - 27541160
AN - SCOPUS:84982281653
SN - 0721-832X
VL - 254
SP - 1977
EP - 1986
JO - Graefe's Archive for Clinical and Experimental Ophthalmology
JF - Graefe's Archive for Clinical and Experimental Ophthalmology
IS - 10
ER -