T1 - Design of automated digital eye palpation exam for intraocular pressure measurement
AU - Luce, Alexander V.
AU - Enikov, Eniko T.
AU - Nelson, Bradley J.
PY - 2009
Y1 - 2009
N2 - Elevated intraocular pressure (IOP) is a major risk factor for the degenerative eye disease glaucoma. Accurate indirect measurements of IOP are essential for glaucoma diagnosis and screening. This work presents an experiment developed to measure IOP in-vitro by simulating the technique of digital palpitation tonometry, a technique in which a trained examiner palpates the eyeball using the fingertips of both index fingers to "feel" the stiffness of the eye. The qualitative nature of this method and errors introduced by the subjectivity of the examiner mean that it is rarely used in comparison with other modern-day tonometry methods. However, this technique offers several potential advantages in that it can be performed outside of a clinical setting without the need for instrument sterilization or local anesthesia and may be less subject to measurement errors occurring in patients who have undergone refractive laser eye surgery. In order to quantify the mechanics of digital palpation tonometry, an automated experiment to measure the intraocular pressure of enucleated porcine eyeballs using mechanized digital palpation was designed and tested. This experiment has direct applications towards the development of a next-generation tonometer for glaucoma treatment.
AB - Elevated intraocular pressure (IOP) is a major risk factor for the degenerative eye disease glaucoma. Accurate indirect measurements of IOP are essential for glaucoma diagnosis and screening. This work presents an experiment developed to measure IOP in-vitro by simulating the technique of digital palpitation tonometry, a technique in which a trained examiner palpates the eyeball using the fingertips of both index fingers to "feel" the stiffness of the eye. The qualitative nature of this method and errors introduced by the subjectivity of the examiner mean that it is rarely used in comparison with other modern-day tonometry methods. However, this technique offers several potential advantages in that it can be performed outside of a clinical setting without the need for instrument sterilization or local anesthesia and may be less subject to measurement errors occurring in patients who have undergone refractive laser eye surgery. In order to quantify the mechanics of digital palpation tonometry, an automated experiment to measure the intraocular pressure of enucleated porcine eyeballs using mechanized digital palpation was designed and tested. This experiment has direct applications towards the development of a next-generation tonometer for glaucoma treatment.
UR - http://www.scopus.com/inward/record.url?scp=67650693041&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=67650693041&partnerID=8YFLogxK
U2 - 10.1109/ICCME.2009.4906663
DO - 10.1109/ICCME.2009.4906663
M3 - Conference contribution
AN - SCOPUS:67650693041
SN - 9781424433162
T3 - 2009 ICME International Conference on Complex Medical Engineering, CME 2009
BT - 2009 ICME International Conference on Complex Medical Engineering, CME 2009
T2 - 2009 ICME International Conference on Complex Medical Engineering, CME 2009
Y2 - 9 April 2009 through 11 April 2009
ER -