TY - JOUR
T1 - Depth-sensitive reflectance measurements using obliquely oriented fiber probes
AU - Wang, Adrien Ming Jer
AU - Bender, Janelle Elise
AU - Pfefer, Joshua
AU - Utzinger, Urs
AU - Drezek, Rebekah Anna
N1 - Funding Information:
Thanks to Vengadesan Nammalvar for his relentless intellectual support, and Nastassja Lewinski for her invaluable editorial assistance. This work is supported by Whitaker RG-02-0125, NIH R01CA09841-01A1, NSF BES 022-1544, NSF EEC 0118007, and National Institutes of General Medical Sciences Training Grant BM 08362.
PY - 2005/7
Y1 - 2005/7
N2 - Computer simulation is used to facilitate the design of fiberprobe geometries that enable enhanced detection of optical signals, arising from specific tissue depths. Obtaining understanding of the relationship between fiber-probe design and tissue interrogation is critical when developing strategies for optical detection of epithelial precancers that originate at known depths from the tissue surface. The accuracy of spectroscopic diagnostics may be enhanced by discretely probing the optical properties of epithelium and underlying stroma, within which the morphological and biochemical features vary as a function of depth. While previous studies have investigated controlling tissue-probing depth for fluorescence-based modalities, in this study we focus on the detection of reflected light scattered by tissue. We investigate how the depth of optical interrogation may be controlled through combinations of collection angles, source-detector separations, and numerical apertures. We find that increasing the obliquity of collection fibers at a given source-detector separation can effectively enhance the detection of superficially scattered signals. Fiber numerical aperture provides additional depth selectivity; however, the perturbations in sampling depth achieved through this means are modest relative to the changes generated by modifying the angle of collection and source-detection separation.
AB - Computer simulation is used to facilitate the design of fiberprobe geometries that enable enhanced detection of optical signals, arising from specific tissue depths. Obtaining understanding of the relationship between fiber-probe design and tissue interrogation is critical when developing strategies for optical detection of epithelial precancers that originate at known depths from the tissue surface. The accuracy of spectroscopic diagnostics may be enhanced by discretely probing the optical properties of epithelium and underlying stroma, within which the morphological and biochemical features vary as a function of depth. While previous studies have investigated controlling tissue-probing depth for fluorescence-based modalities, in this study we focus on the detection of reflected light scattered by tissue. We investigate how the depth of optical interrogation may be controlled through combinations of collection angles, source-detector separations, and numerical apertures. We find that increasing the obliquity of collection fibers at a given source-detector separation can effectively enhance the detection of superficially scattered signals. Fiber numerical aperture provides additional depth selectivity; however, the perturbations in sampling depth achieved through this means are modest relative to the changes generated by modifying the angle of collection and source-detection separation.
KW - Epithelial tissue
KW - Fiber optic probes
KW - Monte Carlo
KW - Reflectance spectroscopy
UR - http://www.scopus.com/inward/record.url?scp=32944455955&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=32944455955&partnerID=8YFLogxK
U2 - 10.1117/1.1989335
DO - 10.1117/1.1989335
M3 - Article
C2 - 16178650
AN - SCOPUS:32944455955
SN - 1083-3668
VL - 10
JO - Journal of biomedical optics
JF - Journal of biomedical optics
IS - 4
M1 - 044017
ER -