TY - JOUR
T1 - Continuous oscillation
T2 - Outcome in critically III patients
AU - Traver, Gayle A.
AU - Tyler, Martha L.
AU - Hudson, Leonard D.
AU - Sherrill, Duane L.
AU - Quan, Stuart F.
PY - 1995/9
Y1 - 1995/9
N2 - Purpose: To compare turning by an oscillating bed to standard 2-hour turning. Outcomes were survival, length of stay (LOS), duration of mechanical ventilation, and incidence of pneumonia. Methods: One hundred and three intensive care patients were randomly assigned to standard turning or turning by an oscillating bed. Data, collected at baseline, daily for 7 days, and then three times weekly until study discharge, included demographics, initial Acute Physiology and Chronic Health Evaluation (APACHE II) score, ventilatory/gas exchange parameters, indicators of pneumonia, nursing measures, and chest roentgenograph. Results: There were no significant differences for LOS, duration of ventilation, nor incidence of pneumonia. Higher survival for subjects on the oscillating bed reached borderline significance (P = .056) for subjects with APACHE II greater than or equal to 20. Longitudinal data were analyzed using the random effects model. No differences in ventilatory or gas exchange parameters were identified. Among subjects who developed pneumonia there was a significantly higher respiratory score (nursing acuity scale) for subjects on the oscillating bed. Conclusions: In selected critically ill patients oscillating therapy may improve survival and improve airway clearance. The frequency and degree of turning needed to prevent complications and improve outcome remains unclear. These newer beds should be used with discrimination so as to not increase hospital costs unnecessarily.
AB - Purpose: To compare turning by an oscillating bed to standard 2-hour turning. Outcomes were survival, length of stay (LOS), duration of mechanical ventilation, and incidence of pneumonia. Methods: One hundred and three intensive care patients were randomly assigned to standard turning or turning by an oscillating bed. Data, collected at baseline, daily for 7 days, and then three times weekly until study discharge, included demographics, initial Acute Physiology and Chronic Health Evaluation (APACHE II) score, ventilatory/gas exchange parameters, indicators of pneumonia, nursing measures, and chest roentgenograph. Results: There were no significant differences for LOS, duration of ventilation, nor incidence of pneumonia. Higher survival for subjects on the oscillating bed reached borderline significance (P = .056) for subjects with APACHE II greater than or equal to 20. Longitudinal data were analyzed using the random effects model. No differences in ventilatory or gas exchange parameters were identified. Among subjects who developed pneumonia there was a significantly higher respiratory score (nursing acuity scale) for subjects on the oscillating bed. Conclusions: In selected critically ill patients oscillating therapy may improve survival and improve airway clearance. The frequency and degree of turning needed to prevent complications and improve outcome remains unclear. These newer beds should be used with discrimination so as to not increase hospital costs unnecessarily.
UR - http://www.scopus.com/inward/record.url?scp=0029123101&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0029123101&partnerID=8YFLogxK
U2 - 10.1016/0883-9441(95)90000-4
DO - 10.1016/0883-9441(95)90000-4
M3 - Article
C2 - 7496451
AN - SCOPUS:0029123101
SN - 0883-9441
VL - 10
SP - 97
EP - 103
JO - Journal of Critical Care
JF - Journal of Critical Care
IS - 3
ER -