TY - JOUR
T1 - Comparison of Sarns 3M heparin bonded to Duraflo II and control circuits in a porcine model
T2 - Macro- and microanalysis of thrombi accumulation in circuit arterial filters
AU - Larson, Douglas F.
AU - Arzouman, David
AU - Kleinert, Leigh
AU - Patula, Vangie
AU - Williams, Stuart
PY - 2000
Y1 - 2000
N2 - Heparin-bonded perfusion circuits have been reported to reduce the thrombus formation during various levels of systemic heparinization. The goal of this study was to compare the efficacy of thrombo-resistance of the Sarns 3M heparin-bonded circuit to Baxter Duraflo II and untreated control in a porcine model. Fifteen Yorkshire pigs (60-65 kg) were anesthetized, heparinized with 3000 IU, intravenously (i.v.) and surgically cannulated with an internal jugular outflow and a femoral vein inflow. All circuits consisted of a 22-Fr venous cannula, centrifugal pump, arterial filter, an 18-Fr cannula for return and connected with equal lengths of 3/8' polyvinyl chloride tubing. The flows were maintained at 2.0 l/min for 4 h. Thrombus formation in filter samples were morphometrically analyzed through macro-densitometry, light microscopy, and scanning electron microscopy (SEM). Our findings revealed that the 3M circuit had significantly less gross thrombus (p < 0.001), 66% and 84% less microscopic thrombi and fivefold less SEM-measured aggregates (p = 0.03) compared to the Duraflo II and uncoated groups. This study demonstrated that the 3M heparin-bonded circuit had significantly reduced the formation of micro- and macro-thrombi in the minimally heparinized pig model compared to the Duraflo II and untreated control circuits.
AB - Heparin-bonded perfusion circuits have been reported to reduce the thrombus formation during various levels of systemic heparinization. The goal of this study was to compare the efficacy of thrombo-resistance of the Sarns 3M heparin-bonded circuit to Baxter Duraflo II and untreated control in a porcine model. Fifteen Yorkshire pigs (60-65 kg) were anesthetized, heparinized with 3000 IU, intravenously (i.v.) and surgically cannulated with an internal jugular outflow and a femoral vein inflow. All circuits consisted of a 22-Fr venous cannula, centrifugal pump, arterial filter, an 18-Fr cannula for return and connected with equal lengths of 3/8' polyvinyl chloride tubing. The flows were maintained at 2.0 l/min for 4 h. Thrombus formation in filter samples were morphometrically analyzed through macro-densitometry, light microscopy, and scanning electron microscopy (SEM). Our findings revealed that the 3M circuit had significantly less gross thrombus (p < 0.001), 66% and 84% less microscopic thrombi and fivefold less SEM-measured aggregates (p = 0.03) compared to the Duraflo II and uncoated groups. This study demonstrated that the 3M heparin-bonded circuit had significantly reduced the formation of micro- and macro-thrombi in the minimally heparinized pig model compared to the Duraflo II and untreated control circuits.
UR - http://www.scopus.com/inward/record.url?scp=0033971148&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0033971148&partnerID=8YFLogxK
U2 - 10.1177/026765910001500103
DO - 10.1177/026765910001500103
M3 - Article
C2 - 10676863
AN - SCOPUS:0033971148
SN - 0267-6591
VL - 15
SP - 13
EP - 20
JO - Perfusion
JF - Perfusion
IS - 1
ER -