Abstract
BACKGROUND AND PURPOSE: MRV has been proposed as a possible screening method to identify chronic cerebrospinal venous insufficiency, which may play a role in MS. We report our initial experience comparing MRV and CV in MS patients to evaluate venous stenosis and collateral venous drainage. MATERIALS AND METHODS: Time-of-flight and time-resolved imaging of contrast kinetics MRV and CV were performed in 39 MS patients. The presence and severity of both IJ vein caliber changes and non-IJ collaterals were graded by using a 4-point scale by 2 radiologists in an independent and blinded manner. RESULTS: Both studies frequently showed venous abnormalities, most commonly IJ flattening at the C1 level and in the lower neck. There was moderate-to-good agreement between the modalities (κ = 0.55; 95% CI, 0.45%-0.65%). For collaterals, agreement was only fair (κ = 0.30; 95% CI, 0.09%-0.50%). The prevalence of IJ segments graded mild or worse on CV was 54%. If CV was considered a standard, the sensitivity and specificity of MRV was 0.79 (0.71-0.86) and 0.76 (0.67-0.83), respectively. Degree of stenosis was related to the severity of collaterals for CV but not for MRV. CONCLUSIONS: IJ caliber changes were seen in characteristic locations on both MRV and CV in MS patients. Agreement between modalities was higher for stenosis than for collaterals. If CV is considered a standard, MRV performance is good but may require additional improvement before MRV can be used for screening.
Original language | English (US) |
---|---|
Pages (from-to) | 1482-1489 |
Number of pages | 8 |
Journal | American Journal of Neuroradiology |
Volume | 32 |
Issue number | 8 |
DOIs | |
State | Published - Sep 2011 |
Externally published | Yes |
ASJC Scopus subject areas
- Radiology Nuclear Medicine and imaging
- Clinical Neurology