N2 - Objective To determine if the CHA2DS2-VASc score (congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, stroke or transient ischemic attack, vascular disease, age 65-74 years, sex category) predicts thromboembolism and death in patients without atrial fibrillation in a population with implantable cardiac monitoring devices. Patients and Methods A retrospective review utilizing the Rochester Epidemiology Project research infrastructure was conducted to evaluate the CHA2DS2-VASc tool as a predictor of mortality and ischemic stroke, transient ischemic attack, or systemic embolism in patients without atrial fibrillation. An implantable device was required in the inclusion criteria to discern the absence of atrial fibrillation. The study period was January 1, 2004, through March 7, 2016. Results The study population (N=1606) had a mean (SD) age of 69.8 (12.6) years and median follow-up of 4.8 years (range, 0-12 years; quartile 1, 2.6 years and quartile 3, 8.1 years). The number of thromboembolic and mortality events stratified by CHA2DS2-VASc score groupings of 0 to 2 (399 patients), 3 to 5 (756 patients), and 6 to 9 (451 patients) were 12 (3.0%), 109 (14.4%), and 123 (27.3%) and 22 (5.5%), 205 (27.1%), and 214 (47.4%), respectively. The CHA2DS2-VASc score predicted thromboembolism and death. The hazard ratios (HRs) for thromboembolic events for CHA2DS2-VASc scores 3 to 5 and 6 to 9 were 4.84 (95% CI, 2.66-8.80) and 10.53 (95% CI, 5.77-19.21) (reference group, scores 0-2). The HRs for death for the corresponding score categories were 4.45 (95% CI, 2.86-6.91) and 8.18 (95% CI, 5.23-12.78). The CHA2DS2-VASc score also predicted development of atrial fibrillation, for which the HRs for scores 3 to 5 and 6 to 9 were 1.51 (95% CI, 1.13-2.00) and 2.17 (95% CI, 1.60-2.95). Conclusion The CHA2DS2-VASc tool predicts thromboembolic events and overall mortality in patients without atrial fibrillation who have implantable devices.
AB - Objective To determine if the CHA2DS2-VASc score (congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, stroke or transient ischemic attack, vascular disease, age 65-74 years, sex category) predicts thromboembolism and death in patients without atrial fibrillation in a population with implantable cardiac monitoring devices. Patients and Methods A retrospective review utilizing the Rochester Epidemiology Project research infrastructure was conducted to evaluate the CHA2DS2-VASc tool as a predictor of mortality and ischemic stroke, transient ischemic attack, or systemic embolism in patients without atrial fibrillation. An implantable device was required in the inclusion criteria to discern the absence of atrial fibrillation. The study period was January 1, 2004, through March 7, 2016. Results The study population (N=1606) had a mean (SD) age of 69.8 (12.6) years and median follow-up of 4.8 years (range, 0-12 years; quartile 1, 2.6 years and quartile 3, 8.1 years). The number of thromboembolic and mortality events stratified by CHA2DS2-VASc score groupings of 0 to 2 (399 patients), 3 to 5 (756 patients), and 6 to 9 (451 patients) were 12 (3.0%), 109 (14.4%), and 123 (27.3%) and 22 (5.5%), 205 (27.1%), and 214 (47.4%), respectively. The CHA2DS2-VASc score predicted thromboembolism and death. The hazard ratios (HRs) for thromboembolic events for CHA2DS2-VASc scores 3 to 5 and 6 to 9 were 4.84 (95% CI, 2.66-8.80) and 10.53 (95% CI, 5.77-19.21) (reference group, scores 0-2). The HRs for death for the corresponding score categories were 4.45 (95% CI, 2.86-6.91) and 8.18 (95% CI, 5.23-12.78). The CHA2DS2-VASc score also predicted development of atrial fibrillation, for which the HRs for scores 3 to 5 and 6 to 9 were 1.51 (95% CI, 1.13-2.00) and 2.17 (95% CI, 1.60-2.95). Conclusion The CHA2DS2-VASc tool predicts thromboembolic events and overall mortality in patients without atrial fibrillation who have implantable devices.
UR - http://www.scopus.com/inward/record.url?scp=85014080595&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85014080595&partnerID=8YFLogxK
U2 - 10.1016/j.mayocp.2016.10.008
DO - 10.1016/j.mayocp.2016.10.008
M3 - Article
C2 - 28259228
AN - SCOPUS:85014080595
SN - 0025-6196
VL - 92
SP - 360
EP - 369
JO - Mayo Clinic Proceedings
JF - Mayo Clinic Proceedings
IS - 3
ER -