TY - JOUR
T1 - Biocompatible PEDOT:Nafion composite electrode coatings for selective detection of neurotransmitters in vivo
AU - Vreeland, Richard F.
AU - Atcherley, Christopher W.
AU - Russell, Wilfred S.
AU - Xie, Jennifer Y.
AU - Lu, Dong
AU - Laude, Nicholas D.
AU - Porreca, Frank
AU - Heien, Michael L.
N1 - Publisher Copyright:
© 2015 American Chemical Society.
PY - 2015/3/3
Y1 - 2015/3/3
N2 - A Nafion and poly(3,4-ethylenedioxythiophene) (PEDOT) containing composite polymer has been electropolymerized on carbon-fiber microelectrodes with the goal of creating a mechanically stable, robust, and controllable electrode coating that increases the selectivity and sensitivity of in vivo electrochemical measurements. The coating is deposited on carbon-fiber microelectrodes by applying a triangle waveform from +1.5 V to -0.8 V and back in a dilute solution of ethylenedioxythiophene (EDOT) and Nafion in acetonitrile. Scanning electron microscopy demonstrated that the coating is uniform and ∼100 nm thick. Energy-dispersive X-ray spectroscopy demonstrated that both sulfur and fluorine are present in the coating, indicating the incorporation of PEDOT (poly(3,4-ethylenedioxythiophene) and Nafion. Two types of PEDOT:Nafion coated electrodes were then analyzed electrochemically. PEDOT:Nafion-coated electrodes made using 200 μM EDOT exhibit a 10-90 response time of 0.46 ± 0.09 s versus 0.45 ± 0.11 s for an uncoated fiber in response to a 1.0 μM bolus of dopamine. The electrodes coated using a higher EDOT concentration (400 μM) are slower with a 10-90 response time of 0.84 ± 0.19 s, but display increased sensitivity to dopamine, at 46 ± 13 nA/μM, compared to 26 ± 6 nA/μM for the electrodes coated in 200 μM EDOT and 13 ± 2 nA/μM for an uncoated fiber. PEDOT:Nafion-coated electrodes were lowered into the nucleus accumbens of a rat, and both spontaneous and electrically evoked dopamine release were measured. In addition to improvements in sensitivity and selectivity, the coating dramatically reduces acute in vivo biofouling.
AB - A Nafion and poly(3,4-ethylenedioxythiophene) (PEDOT) containing composite polymer has been electropolymerized on carbon-fiber microelectrodes with the goal of creating a mechanically stable, robust, and controllable electrode coating that increases the selectivity and sensitivity of in vivo electrochemical measurements. The coating is deposited on carbon-fiber microelectrodes by applying a triangle waveform from +1.5 V to -0.8 V and back in a dilute solution of ethylenedioxythiophene (EDOT) and Nafion in acetonitrile. Scanning electron microscopy demonstrated that the coating is uniform and ∼100 nm thick. Energy-dispersive X-ray spectroscopy demonstrated that both sulfur and fluorine are present in the coating, indicating the incorporation of PEDOT (poly(3,4-ethylenedioxythiophene) and Nafion. Two types of PEDOT:Nafion coated electrodes were then analyzed electrochemically. PEDOT:Nafion-coated electrodes made using 200 μM EDOT exhibit a 10-90 response time of 0.46 ± 0.09 s versus 0.45 ± 0.11 s for an uncoated fiber in response to a 1.0 μM bolus of dopamine. The electrodes coated using a higher EDOT concentration (400 μM) are slower with a 10-90 response time of 0.84 ± 0.19 s, but display increased sensitivity to dopamine, at 46 ± 13 nA/μM, compared to 26 ± 6 nA/μM for the electrodes coated in 200 μM EDOT and 13 ± 2 nA/μM for an uncoated fiber. PEDOT:Nafion-coated electrodes were lowered into the nucleus accumbens of a rat, and both spontaneous and electrically evoked dopamine release were measured. In addition to improvements in sensitivity and selectivity, the coating dramatically reduces acute in vivo biofouling.
UR - http://www.scopus.com/inward/record.url?scp=84923886817&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84923886817&partnerID=8YFLogxK
U2 - 10.1021/ac502165f
DO - 10.1021/ac502165f
M3 - Article
C2 - 25692657
AN - SCOPUS:84923886817
SN - 0003-2700
VL - 87
SP - 2600
EP - 2607
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 5
ER -