TY - JOUR
T1 - Application of heated inlet extensions to the TSI 3306/3321 system
T2 - Comparison with the Andersen cascade impactor and next generation impactor
AU - Myrdal, Paul B.
AU - Mogalian, Erik
AU - Mitchell, Jolyon
AU - Nagel, Mark
AU - Wright, Charlie
AU - Kiser, Brent
AU - Prell, Mark
AU - Woessner, Mike
AU - Stein, Stephen W.
PY - 2006
Y1 - 2006
N2 - Pharmaceutical aerosol size distribution analysis based on multi-stage inertial impaction is well accepted, though laborious. The TSI 3306 Impactor Inlet/3321 time-of-flight (TOF) Aerodynamic Particle Size Analyzer (APS®) has been evaluated for its ease of use and potential for time savings during product development. However, instrument inlet modifications may be necessary for increased correlation with equivalent measurements obtained by inertial impaction following pharmacopeial methods. A heated inlet extension tube was located between the USP/Ph.Eur. throat and the Single-Stage Impactor (SSI) to promote evaporation of residual ethanol from aerosol droplets, generated from two formulations containing ethanol as semi-volatile solubilizer (8 and 20% w/w) for the active pharmaceutical ingredient. As temperature and extension length increased, the SSI-measured fine particle fraction (aerosol < 4.7 μm aerodynamic diameter) also increased, for the aerosols used in this study. These values correlated quite closely with equivalent measures made by multi-stage cascade impactor equipped with the same throat. Particle size distribution profiles measured with the APS for either formulation did not significantly change utilizing the heated extensions, suggesting that ethanol evaporation was largely complete at any condition by the time the aerosol entered the measurement zone of the TOF analyzer. The addition of a heated inlet extension may be useful to facilitate evaporation of residual semi-volatile species, especially when an agreement of APS-derived particle size mass distribution data from the SSI with multi-stage cascade impactors is desired. However, complete evaporation of the semi-volatile species may not be necessary for SSI-generated mass distribution to match conventionally used cascade impactors.
AB - Pharmaceutical aerosol size distribution analysis based on multi-stage inertial impaction is well accepted, though laborious. The TSI 3306 Impactor Inlet/3321 time-of-flight (TOF) Aerodynamic Particle Size Analyzer (APS®) has been evaluated for its ease of use and potential for time savings during product development. However, instrument inlet modifications may be necessary for increased correlation with equivalent measurements obtained by inertial impaction following pharmacopeial methods. A heated inlet extension tube was located between the USP/Ph.Eur. throat and the Single-Stage Impactor (SSI) to promote evaporation of residual ethanol from aerosol droplets, generated from two formulations containing ethanol as semi-volatile solubilizer (8 and 20% w/w) for the active pharmaceutical ingredient. As temperature and extension length increased, the SSI-measured fine particle fraction (aerosol < 4.7 μm aerodynamic diameter) also increased, for the aerosols used in this study. These values correlated quite closely with equivalent measures made by multi-stage cascade impactor equipped with the same throat. Particle size distribution profiles measured with the APS for either formulation did not significantly change utilizing the heated extensions, suggesting that ethanol evaporation was largely complete at any condition by the time the aerosol entered the measurement zone of the TOF analyzer. The addition of a heated inlet extension may be useful to facilitate evaporation of residual semi-volatile species, especially when an agreement of APS-derived particle size mass distribution data from the SSI with multi-stage cascade impactors is desired. However, complete evaporation of the semi-volatile species may not be necessary for SSI-generated mass distribution to match conventionally used cascade impactors.
KW - Andersen cascade impactor
KW - Impactor inlet
KW - MDI
KW - Metered dose inhaler
KW - Next generation impactor
UR - http://www.scopus.com/inward/record.url?scp=33846074001&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33846074001&partnerID=8YFLogxK
U2 - 10.1089/jam.2006.19.543
DO - 10.1089/jam.2006.19.543
M3 - Article
C2 - 17196082
AN - SCOPUS:33846074001
SN - 0894-2684
VL - 19
SP - 543
EP - 554
JO - Journal of Aerosol Medicine: Deposition, Clearance, and Effects in the Lung
JF - Journal of Aerosol Medicine: Deposition, Clearance, and Effects in the Lung
IS - 4
ER -