Abstract
AAA repair in renal transplant recipients has generated a variety of methods of managing the allograft. Endovascular techniques have been successfully employed in this patient population. Due to inherent limitations of present endovascular methods, occasional stent-graft excision must be performed. We present a case of aortic stent-graft excision in a renal transplant recipient using a pump-oxygenator to maintain allograft perfusion.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 535.e21-535.e26 |
| Journal | Annals of Vascular Surgery |
| Volume | 23 |
| Issue number | 4 |
| DOIs | |
| State | Published - 2009 |
| Externally published | Yes |
ASJC Scopus subject areas
- Surgery
- Cardiology and Cardiovascular Medicine