Anterior chamber depth in normal subjects by rotating scheimpflug imaging

Matthew T. Feng, Michael W. Belin, Renato Ambrósio, Satinder P.S. Grewal, Wang Yan, Mohamed S. Shaheen, Charles McGhee, Naoyuki Maeda, Tobias H. Neuhann, H. Burkhard Dick, Saleh A. Alageel, Andreas Steinmueller

Research output: Contribution to journalArticlepeer-review

26 Scopus citations

Abstract

Purpose: Anterior chamber depth (ACD) is an important preoperative parameter in anterior segment surgery. Several factors are known to influence ACD, including race and geography. Our purpose was to sample data from various countries to characterize differences in ACD worldwide and, if any, assess their level of clinical significance. Setting: International, multicenter. Methods: Cross-sectional study. Using the Pentacam Eye Scanner (OCULUS GmbH, Wetzlar, Germany), we analyzed ACD measurements from 1077 eyes of 568 normal adults from nine countries spanning six continents. Differences between countries were assessed by comparison of 95% confidence intervals and by ANOVA. Normative thresholds were constructed at three standard deviations (SD) above and below the mean. Results: Mean ACD was 3.11. mm overall, ranging from 2.91. mm (New Zealand) to 3.24. mm (United States). The ACD among New Zealanders was significantly shallower (P< .0001) than that among Chinese, Egyptians, Germans, Indians, and Americans. The maximum difference in the mean ACDs was 0.33. mm, between New Zealand and the United States. The shallowest 0.15% of normal ACD values occurred below 2.04. mm overall, ranging from 1.69. mm (New Zealand) to 2.42. mm (United States). The deepest 0.15% of normal ACD values occurred above 4.18. mm overall, ranging from 4.03. mm (Saudi Arabia) to 4.35. mm (Brazil). Conclusions: ACD did not vary significantly in the countries studied, with the notable exception of New Zealand. Surgeons should anticipate a greater likelihood of a shallow ACD when evaluating patients from New Zealand. Clinical examination and direct measurement of ACD are recommended. Finally, deep ACD has limited clinical utility in screening for keratoconus.

Original languageEnglish (US)
Pages (from-to)255-259
Number of pages5
JournalSaudi Journal of Ophthalmology
Volume25
Issue number3
DOIs
StatePublished - Jul 2011

Keywords

  • Anterior chamber depth
  • International
  • Pentacam
  • Scheimpflug

ASJC Scopus subject areas

  • Ophthalmology

Fingerprint

Dive into the research topics of 'Anterior chamber depth in normal subjects by rotating scheimpflug imaging'. Together they form a unique fingerprint.

Cite this