TY - JOUR
T1 - Adverse respiratory effects following overhaul in firefighters
AU - Burgess, Jefferey L.
AU - Nanson, Christopher J.
AU - Bolstad-Johnson, Dawn M.
AU - Gerkin, Richard
AU - Hysong, Tracy A.
AU - Lantz, R. Clark
AU - Sherrill, Duane L.
AU - Crutchfield, Clifton D.
AU - Quan, Stuart F.
AU - Bernard, Alfred M.
AU - Witten, Mark L.
PY - 2001/5
Y1 - 2001/5
N2 - Overhaul is the stage in which firefighters search for and extinguish possible sources of reignition. It is common practice not to wear respiratory protection during overhaul. Fifty-one firefighters in two groups, 25 without respiratory protection and 26 wearing cartridge respirators, were monitored for exposure to products of combustion and changes in spirometric measurements and lung permeability following overhaul of a structural fire. Testing at baseline and 1 hour after overhaul included forced vital capacity (FVC), forced expiratory volume in one second (FEV1), serum Clara cell protein (CC16), and serum surfactant-associated protein A (SP-A). Overhaul increased CC16 in both groups, indicating increased alveolar-capillary membrane permeability. Contrary to expectations, SP-A increased and FVC and FEV1 decreased in the firefighters wearing cartridge respirators. Changes in FEV1, CC16, and SP-A were associated with concentrations of specific products of combustion or carboxyhemoglobin levels. Firefighter exposures during overhaul have the potential to cause changes in spirometric measurements and lung permeability, and self-contained breathing- apparatus should be worn during overhaul to prevent lung injury.
AB - Overhaul is the stage in which firefighters search for and extinguish possible sources of reignition. It is common practice not to wear respiratory protection during overhaul. Fifty-one firefighters in two groups, 25 without respiratory protection and 26 wearing cartridge respirators, were monitored for exposure to products of combustion and changes in spirometric measurements and lung permeability following overhaul of a structural fire. Testing at baseline and 1 hour after overhaul included forced vital capacity (FVC), forced expiratory volume in one second (FEV1), serum Clara cell protein (CC16), and serum surfactant-associated protein A (SP-A). Overhaul increased CC16 in both groups, indicating increased alveolar-capillary membrane permeability. Contrary to expectations, SP-A increased and FVC and FEV1 decreased in the firefighters wearing cartridge respirators. Changes in FEV1, CC16, and SP-A were associated with concentrations of specific products of combustion or carboxyhemoglobin levels. Firefighter exposures during overhaul have the potential to cause changes in spirometric measurements and lung permeability, and self-contained breathing- apparatus should be worn during overhaul to prevent lung injury.
UR - http://www.scopus.com/inward/record.url?scp=17144439174&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=17144439174&partnerID=8YFLogxK
U2 - 10.1097/00043764-200105000-00007
DO - 10.1097/00043764-200105000-00007
M3 - Article
C2 - 11382182
AN - SCOPUS:17144439174
SN - 1076-2752
VL - 43
SP - 467
EP - 473
JO - Journal of occupational and environmental medicine
JF - Journal of occupational and environmental medicine
IS - 5