TY - JOUR
T1 - Accuracy of the PAR Comeal Topography System with spatial misalignment
AU - Belin, Michael W.
AU - Zloty, Peter
PY - 1993/1
Y1 - 1993/1
N2 - The PAR Corneal Topography System is a computerized corneal imaging system which uses close-range raster photogrammetry to measure and produce a topographic map of the corneal surface. Raster photogrammetry is a standard method of extracting object information by projecting a known pattern onto an object and recording the distortion when viewed from an oblique angle. Unlike placido disc based videokeratoscopes, the PAR system requires neither a smooth reflective surface nor precise spatial alignment for accurate imaging. We studied both the accuracy of the system with purposeful misalignment (defocusing) of the test object and determined the ability to image freshly deepithelialized, keratectomized, and photoablated corneas. The PAR system was both accurate and reproducible in imaging calibrated spheres within a defined zone in space. Whole cadaver eyes were imaged both before and immediately after removal of the epithelium, lamellar keratectomy, and laser photoablation. The system demonstrated the ability to image irregular, deepithelialized, and keratectomized corneas. The ability to maintain accuracy without precise alignment and the facility to image freshly deepithelialized and keratectomized corneas may make the system suitable for intraoperative refractive monitoring.
AB - The PAR Corneal Topography System is a computerized corneal imaging system which uses close-range raster photogrammetry to measure and produce a topographic map of the corneal surface. Raster photogrammetry is a standard method of extracting object information by projecting a known pattern onto an object and recording the distortion when viewed from an oblique angle. Unlike placido disc based videokeratoscopes, the PAR system requires neither a smooth reflective surface nor precise spatial alignment for accurate imaging. We studied both the accuracy of the system with purposeful misalignment (defocusing) of the test object and determined the ability to image freshly deepithelialized, keratectomized, and photoablated corneas. The PAR system was both accurate and reproducible in imaging calibrated spheres within a defined zone in space. Whole cadaver eyes were imaged both before and immediately after removal of the epithelium, lamellar keratectomy, and laser photoablation. The system demonstrated the ability to image irregular, deepithelialized, and keratectomized corneas. The ability to maintain accuracy without precise alignment and the facility to image freshly deepithelialized and keratectomized corneas may make the system suitable for intraoperative refractive monitoring.
UR - http://www.scopus.com/inward/record.url?scp=0027536610&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0027536610&partnerID=8YFLogxK
U2 - 10.1097/00140068-199301000-00012
DO - 10.1097/00140068-199301000-00012
M3 - Article
C2 - 8453756
AN - SCOPUS:0027536610
SN - 1542-2321
VL - 19
SP - 64
EP - 68
JO - Eye and Contact Lens
JF - Eye and Contact Lens
IS - 1